Datasheet

UK
Archcliffe Road Dover
CT17 9EN England
T +44 (0) 1304 502101
F +44 (0) 1304 207342
UKsales@megger.com
UNITED STATES
4271 Bronze Way
Dallas TX 75237-1019 USA
T 800 723 2861 (USA only)
T +1 214 333 3201
F +1 214 331 7399
USsales@megger.com
OTHER TECHNICAL SALES OFFICES
Valley Forge USA, College Station USA,
Sydney AUSTRALIA, Danderyd SWEDEN,
Ontario CANADA, Trappes FRANCE,
Oberursel GERMANY, Aargau SWITZERLAND,
Kingdom of BAHRAIN, Mumbai INDIA,
Johannesburg SOUTH AFRICA, Chonburi THAILAND
CERTIFICATION ISO
Registered to ISO 9001:2000 Cert. no. Q 09290
MFT1800_DS_eu_V11
www.megger.com
Megger is a registered trademark
4
ORDERING INFORMATION
Description Order Code
MFT1815-AU 1005-270
MFT1815-CH-DE/FR 1002-402
MFT1815-SC-DE/NL/EN 1002-403
MFT1815-SC-FR/ES 1002-405
MFT1825-AU 1002-406
MFT1825-CH-DE/FR 1002-407
MFT1825-SC-DE/NL/EN 1002-408
MFT1825-SC-FR/ES 1002-410
MFT1835-AU 1002-411
MFT1835-CH-DE/FR 1002-620
MFT1835-DE+P’KAL Manager software 1002-414
MFT1835-SC-DE/NL/EN 1002-415
MFT1835-SC-FR/ES 1002-417
Included accessories
Printed quickstart guide
Full user guide on CD
Calibration certificate
Description Order Code
Included accessories
Switched probe SP5 1001-878
Neck strap - Megger embroidered 2001-509
3 Wire lead set with prods and clips 1001-991
Euro mains test lead SIA45 (not AU) 2000-674
AU/NZ plug test lead (AU only) 6220-828
AC battery charger (MFT1835 only) 1002-736
Optional accessories
Soft carry case with lead/document pouch 6420-143
Fused 10 A test lead set (red/blue/green) with prods and clips
1001-975
ETL30 Extension Test Lead 30m 1000-215
ETL50 Extension Test Lead 50m 1000-217
Cigar lighter adapter for battery charging. 6280-332
Earth electrode kit 1001-810
DESIGN STANDARDS
Safety
IEC 61010-1:2010
IEC 61010-30:2010
IEC 61010-031:2008
600 V Cat III / 300 V Cat IV (Max Phase to Phase 600 V)
IEC 61557:2007 parts 1 to 10
EMC IEC61326 edition 2 location class B
ENVIRONMENTAL
Operating
temperature
range and
humidity
-10 °C ~ +55 °C
90% R.H. at +40 °C max
Temperature
(storage)
-25 °C ~ +70 °C
Maximum
altitude
2000 m
Weight
(instrument and
case)
1 kg (with batteries, excluding case)
Dimensions
(instrument and
case)
150 x 85 x 235 mm
IP rating IP54
Calibration
temperature
+20 °C
TEMPERATURE EFFECTS
Temperature co-
efficient
<0,1% per °C