Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 Logistic Tray mLog2 User Manual Rev. 1.0 Model: mLog2 Technical Contacts and Enquiry: raymondli@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 Table of Content FCC statement..................................................................................................... 3 CE statement ....................................................................................................... 3 Chapter 1 Introduction of Logistic Tray mLog2 ............................................. 4 1.1 Overview of Logistic Tray mLog2 ......................................................
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 FCC statement FCC NOTICE: To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 Chapter 1 Introduction of Logistic Tray mLog2 1.1 Overview of Logistic Tray mLog2: Logistic Tray is an UHF EPC C1G2 RFID fixed reader, it is embedded with strong near field antenna and only read tag on the tray, minimize the false reading issue.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 1.2 Ports Description The Logistic Tray mLog2 has several types of input/output port: Items no. Name Description 1 DC jack 6.5V/3A dc power supply input 2 USB port One standard USB port 3 On_OFF switch One switch on and off button Technical Contacts and Enquiry: raymondli@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 1.3 Indicators LEDs in Logistic Tray mLog2 The Logistic Tray mLog2 has different LEDs to indicate the reader status. Items no. Name Description 4 Red LED Powered On but USB not connect 5 Blue LED Powered On and USB Connected Technical Contacts and Enquiry: raymondli@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 1.4 Antenna for Logistic Tray mLog2 There are two identical antennas are used with Logistic Tray mLog2. The following antennas are used for Logistic Tray mLog2: RFID NEAR FIELD FLAT PANEL ANTENNA: antenna gain = 0dBi Technical Contacts and Enquiry: raymondli@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 1.5 Specification: Item Input Indicator Connectivity Charger Operation temp. Storage temp. Operating Humidity Features Specification 1 power key button 1 USB port Red LED indicate for Powered On but USB not connected Blue LED indicate for Powered On and USB Connected USB2.0 6.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 Chapter 2 Installation of Logistic Tray mLog2 2.1 Start-up Procedure of Logistic Tray mLog2 This section explains how to set-up Logistic Tray mLog2 and connect the Logistic Tray mLog2 to your computer and antenna: I. Plug in the power adapter. II. Power on the mLog2 by switching the Power on button. Then, the Red LED will be turned on. Technical Contacts and Enquiry: raymondli@myndar.com Website: www.myndar.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 III. Plug in the USB to the tray and connect the USB with the computer. Then, the Blue LED will be turned on. IV. Select the test tools or apps for application. V. Logistic Tray mLog2 operates at UHF frequency band, ranging from 865MHz to 928MHz (ETSI 865-868 MHz, FCC 902-928 MHz, SRRC 920-925 MHz and NCC 922-928 MHz); the setting depends on countries’ regulations. 2.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 2.3 Caution Danger of Electric Shock • Disconnect the device from the electric supply before cleaning or performing maintenance on the machine. • • Keep this device dry. Turn off or unplug the machine when it is not in use. Please read the information contained within this user manual prior to attempting installation and operation of the RFID Reader.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 2.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 Federal Communications Commission (FCC) Compliance These products operate at the following frequencies in compliance with Part 15 of the FCC rules: RFID; 902 MHz - 928 MHz, Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 frequency energy that can be safely absorbed by a user or bystander according to the intended usage of the product. This product has been tested and found to comply with the FCC criteria. The LOGISTIC TRAY mLog2 shall be installed & used such that parts of the user’s body and the hands should be maintained at a comfortable distance of approximately 25 cm or more.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 Chapter 3 Demonstration of RFID Applications 3.1 Creating RFID Application with Logistic Tray mLog2 Logistic Tray mLog2 is an intelligent reader and compliance with EPC global C1G2/ISO 18000-6C, Users can develop own UHF RFID application on this platform. 3.1.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 Chapter 4 Regulatory Information 4.1 Federal Communications Commission (FCC) Compliance This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 4.1.1 Radio Frequency Radiation Exposure The highest RF output power of the unit was measured at 30.0dBm at 915 MHz. According to §1.1310 of the FCC rules, the power density limit for General Population/Uncontrolled Exposure at 915 MHz is f(MHz)/1500 = 0.610mW/cm2. The MPE is calculated to show the required separation distance that must be maintained during installation to maintain compliance with the power density limit.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 4.2 CE Compliance This device has been tested to and conforms to the regulatory requirements of the European Union and has attained CE Marking. The CE Mark is a conformity marking consisting of the letters "CE". The CE Mark applies to products regulated by certain European health, safety and environmental protection legislation.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 Chapter 5 Disclaimer Notice Disclaimer Notice The manufacturer shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. This document contains proprietary information, which is protected by international patent applications and copyright. All rights reserved.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 Chapter 6 Warranty 1. Megabyte Ltd warrants to the User that the Products sold to the User will comply with their published specifications and will be of satisfactory quality and that Megabyte Ltd is entitled to sell the Products to the User. Megabyte Ltd warrants that for a period of twelve (12) months from date of purchase (“the Warranty Period”), the products will be free from defects in materials and workmanship. 2.
Logistic Tray mLog2 User Manual Rev. 1.0 Updated on 29September 2019 Chapter 7 Support Technical support/Sales Enquiry can be obtained from Megabyte Ltd. Please email to: raymondli@myndar.com Technical Contacts and Enquiry: raymondli@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.