User's Manual
Table Of Contents
- Table of Contents
- Instructions for use
- Getting started
- Using the SEEQ MCT System during the monitoring period
- What to do at the end of monitoring
- Indications for use, contraindications, and precautions
- Services for physicians
- Specifications, compliance, and symbols
- Frequently asked questions
- What is a Wearable Sensor?
- How long will my Wearable Sensor last?
- What information is transmitted to my physician?
- How can I report my symptoms?
- Can I take a shower while wearing my Wearable Sensor?
- Will I need to change the battery in the Transmitter or the Wearable Sensor?
- How close must I be to the Transmitter to ensure that the data collected by my Wearable Sensor is transmitted?
- How often do I need to change the Wearable Sensor device?
- What if the Wearable Sensor causes my skin to itch?
- Should I carry the Transmitter with me when I travel?
- Will I need to notify security screeners about my Wearable Sensor?
- Can I wear a Wearable Sensor through an electronic antitheft system, such as in a store?
- Can I use microwave ovens or TV remotes while wearing a Wearable Sensor?
- Can I be close to wireless phones, WiFi, or other electromagnetic devices?
- Can I carry my cellphone while wearing the Wearable Sensor?
- Will hot or cold environments affect the Wearable Sensor performance?
- Is my medical data protected during transmission?
6 English SEEQ MCT Instructions for use
M958549A001 Rev B
Refer to doc # A73903 for Printing
Instructions.
M958549A_ch.fm 3/12/15 2:34 pm
4" x 8" (101 mm x 203 mm)
Medtronic Confidential
mdvtldct_R1.5
Step 3: Prepare for Wearable Sensor application
IMPORTANT: Monitoring will be affected if hair is not trimmed or
if skin is not cleaned with the Prep Wipe. If this happens, you
may be required to use another Wearable Sensor.
IMPORTANT: Take care not to touch the adhesive gel while you
handle the Wearable Sensor.
• Trim as much hair as
possible from the intended
location (for men) on the upper
left chest, as seen in the
diagram (for example, using an
electric razor or hair trimmer).
Trim an area slightly larger than
the Wearable Sensor.
• Using the Prep Wipe
provided, clean the skin where
the Wearable Sensor will be
applied and allow time to dry
(clean an area slightly larger
than the Wearable Sensor).
• Do not use any creams or
lotions on your skin before
application as this will impact
monitoring.
• Remove the Wearable Sensor
from the foil pouch by tearing
at the notch. If you see any
illuminated lights on the
Wearable Sensor before
application, contact Medtronic
Customer Support at 1-877-
247-7449.
• Grasp the top side of the
Wearable Sensor as seen in
the diagram and turn it over to
view the underside.
• Carefully remove each tab
from the underside of the
Wearable Sensor to expose
the adhesive gel.