Product Info
Table Of Contents
- M998590A011DOC_A_FINAL_UserGuide_Part2
- Troubleshooting
- Maintenance
- Product specifications and safety information
- Product specifications
- Alarm and alert escalation
- Altitude range
- Audio frequency
- Backlight
- Basal delivery
- BG Target
- BG meter value
- Bolus delivery
- Bolus Wizard feature default settings
- Bolus Wizard feature specifications
- Carb ratios
- Delivery accuracy
- Easy Bolus feature
- Environmental conditions
- Essential performance
- Filling the infusion set and cannula
- Infusion pressure
- Insulin delivery default settings
- Bolus settings
- Basal settings
- Insulin sensitivity factor
- Low Reservoir reminder
- Max Bolus
- Normal bolus
- Occlusion detection
- Percent temp basal
- Program safety checks
- Pump dimensions
- Pump memory
- Pump weight
- Sensor default settings
- Wireless communication
- FCC notice
- IEC60601-1-2:4th Edition notice
- Guidance and manufacturer's declaration
- Icon glossary
- Product specifications
- 670G Performance Data and Technical Information
WARNING: Do not use the Suspend on low feature to prevent or
treat low glucose. Always confirm your sensor glucose reading using
your BG meter, and follow the instructions of your healthcare
professional to treat low glucose. Using Suspend on low alone to
prevent or treat low glucose may result in prolonged hypoglycemia.
Guardian Sensor (3)
The Guardian Sensor (3) is intended for use with the MiniMed 770G system to
continuously monitor glucose levels in persons with diabetes.
The sensor is intended for single use and requires a prescription. The Guardian
Sensor (3) is indicated for 7 days of continuous use.
The Guardian Sensor (3) has been studied and is approved for use in the following
sensor insertion sites by persons of the following ages:
Approved Age Sensor Insertion Site
2-13 Abdomen and Buttocks
14 and older Abdomen and Arm
One-press Serter
The serter is used as an aid for inserting the sensor. It is indicated for single-patient
use and is not intended for multiple patient use.
Guardian Link (3) Transmitter
The Guardian Link (3) Transmitter is intended for use with MiniMed 770G System.
The Guardian Link (3) Transmitter powers the glucose sensor, collects and
calculates sensor data, and wirelessly sends the data to the MiniMed 770G insulin
pump. The Transmitter is intended for single-patient multi-use.
Accu-Chek Guide Link Blood Glucose Monitoring System
The Accu-Chek Guide Link Blood Glucose Monitoring System is comprised of the
Accu-Chek Guide Link meter and the Accu-Chek Guide test strips.
The Accu-Chek Guide Link Blood Glucose Monitoring System is intended to
quantitatively measure glucose in fresh capillary whole blood from the fingertip,
palm, and upper arm as an aid in monitoring the effectiveness of glucose control.