User Manual
Table Of Contents
- Table of contents
- Glossary
- Before you begin...
- The basics...
- Basic programming
- Starting on insulin
- Using Bolus Wizard
- Optimizing pump therapy
- Insulin pump therapy follow-up
- Utilities
- Troubleshooting and alarms
- Troubleshooting
- My pump has a no delivery alarm...
- What happens if I leave the battery out too long?
- Why doesn’t my pump battery last very long?
- What is a CHECK SETTINGS alarm?
- My screen appears distorted...
- I can’t get out of the priming loop...
- The pump is asking me to rewind...
- My bolus stopped...
- My pump buttons are not acting right during a bolus...
- My pump won’t display my BG reading from my meter...
- I dropped my pump
- I submerged my pump in water
- Alarms
- Alarm conditions
- Troubleshooting
- Pump maintenance
- User safety
- Pump specifications
- Alarms and error messages
- Alarm history
- Backlight
- Basal
- BG target
- Bolus delivery
- Bolus history
- Bolus units
- Bolus Wizard
- Carb ratios
- Carb units
- Daily totals
- Default screen
- Delivery accuracy
- Drive motor
- Dual Wave bolus
- Easy bolus
- Infusion pressure
- (insulin) sensitivity
- Insulin type
- Low resv (reservoir) warning
- Meter value
- Normal bolus
- Occlusion detection
- Percent temp basal
- Power supply
- Prime function
- Prime history
- Program safety checks
- Pump size
- Pump weight
- Remote control
- Reservoir
- Square Wave bolus
- Status screen
- Temporary (temp) basal rate
- Time and date screen
- Water tight
- Bolus Wizard specifications
- Default settings
- Icon table
- Menu map
60 Chapter 5
4. The screen will display one of these messages:
MESSAGE What it means
➠“Bolus Wizard setup is complete” .............Bolus Wizard is on and all settings are programmed.
➠“Bolus Wizard is off” .......................................Bolus Wizard is off.
➠“Missing Info”.....................................................Bolus Wizard is on, but some of the settings are not programmed.
This screen will show instructions and the missing information.
You must program the missing information before you can use the
Bolus Wizard.
3. To set just one BG Target: To set more than one BG Target:
a. Press ESC. a. Set the start time for
BG Target 2 and
press ACT.
b. Set the value for
Target BG 2 and
press ACT.
c. Repeat steps a and b to
set more BG Targets.
d. Press ESC when you are
done.
_:_
SET START TIME 2
MiniMed
(flashing)
press ESC
- -
mg/dL
_:_
SET START TIME 2*
MiniMed
(flashing) set, then
press
ACT
- -
mg/dL
_:_
SET TARGET BG 2*
(flashing) set, then
press ACT
- -
mg/dL
MiniMed
* Depending on how many
targets you set, this
number can be 2 through