User Manual
Table Of Contents
- Table of contents
- Glossary
- Before you begin...
- The basics...
- Basic programming
- Starting on insulin
- Using Bolus Wizard
- Optimizing pump therapy
- Insulin pump therapy follow-up
- Utilities
- Troubleshooting and alarms
- Troubleshooting
- My pump has a no delivery alarm...
- What happens if I leave the battery out too long?
- Why doesn’t my pump battery last very long?
- What is a CHECK SETTINGS alarm?
- My screen appears distorted...
- I can’t get out of the priming loop...
- The pump is asking me to rewind...
- My bolus stopped...
- My pump buttons are not acting right during a bolus...
- My pump won’t display my BG reading from my meter...
- I dropped my pump
- I submerged my pump in water
- Alarms
- Alarm conditions
- Troubleshooting
- Pump maintenance
- User safety
- Pump specifications
- Alarms and error messages
- Alarm history
- Backlight
- Basal
- BG target
- Bolus delivery
- Bolus history
- Bolus units
- Bolus Wizard
- Carb ratios
- Carb units
- Daily totals
- Default screen
- Delivery accuracy
- Drive motor
- Dual Wave bolus
- Easy bolus
- Infusion pressure
- (insulin) sensitivity
- Insulin type
- Low resv (reservoir) warning
- Meter value
- Normal bolus
- Occlusion detection
- Percent temp basal
- Power supply
- Prime function
- Prime history
- Program safety checks
- Pump size
- Pump weight
- Remote control
- Reservoir
- Square Wave bolus
- Status screen
- Temporary (temp) basal rate
- Time and date screen
- Water tight
- Bolus Wizard specifications
- Default settings
- Icon table
- Menu map
Pump specifications 125
Status screen
➠ Time and insulin type
(always appears)
➠ Status of pump
(i.e., Rewind, Suspended, Low Reservoir, Set Time, etc.)
➠ Block:
(if active) ON
➠ BG meter value:
(most recent BG value received)
(appears if
BG meter is enabled)
XXXmg/dL
time and date (received)
➠ Last bolus information:
type and units delivered (‘S’-Square, ‘N’-Normal, ‘D’-Dual)
delivery time and date
➠ Basal pattern information
(if active) Pattern A or B
➠ Current temp basal information:
(if currently active)
(if active) rate (units per hour)
duration
time remaining
➠ Standard basal delivery data:
(always appears) current basal rate (basal 1, basal 2, etc.)
➠ Reservoir started:
(always appears) date, time
units left
time left
➠ BG Reminder in:
Time remaining before BG reminder is set to go off H:MM h
(if less than 1 hour, 0:XXh where XX is minutes remaining)
➠ Remote On:
(appears if enabled)
➠ Meter On:
(appears if enabled)
➠ Meter Off, Low Batt:
(appears if enabled but battery is low or empty)
➠ Battery Status:
(always appears) Normal, Low, Off, Weak* (*712 pump only)
➠ Auto-off
(appears if enabled) X HR
➠ Current date:
DDD ## MMM YYYY
➠ Serial number:
(always appears)
➠ Pump model number:
(always appears)
➠ Software version:
(always appears)