Installation Instructions Part 1
Table Of Contents
- Table of Contents
- CHAPTER 1 Description of the Medtronic MiniMed 2007C Implantable Insulin Pump System 11
- CHAPTER 2 Indications and Contraindications 21
- CHAPTER 3 Personal Pump Communicator (PPC) 25
- CHAPTER 4 Pump Implantation 77
- CHAPTER 5 Pump Refill Procedure 97
- CHAPTER 6 Explanting the Pump System 107
- CHAPTER 7 Warnings And Precautions 109
- CHAPTER 8 Adverse Reactions 115
- CHAPTER 9 System Alarms and Messages 117
- CHAPTER 10 Troubleshooting Pump System Under-delivery 131
- CHAPTER 11 MiniMed 2007C Implantable Insulin Pump System 133
- APPENDIX A Label Information 137
- APPENDIX B Implant Worksheet 141
- APPENDIX C Refill Form 143
- APPENDIX D Precautions and General Procedures 145
- APPENDIX E Pump Rinse Procedure 151
- APPENDIX F Side Port Catheter Flush Procedure 163
- APPENDIX G Stroke Volume Measurement 175
- APPENDIX H Pressure Measurement Using The Side Port Catheter 181
- CHAPTER 1 Description of the Medtronic MiniMed 2007C Implantable Insulin Pump System
- CHAPTER 2 Indications and Contraindications
- CHAPTER 3 Personal Pump Communicator (PPC)
- Introduction
- Part 1: PPC/Pump system initialization
- Part 2: Additional PPC programming features
- Main menu
- Program a bolus
- Set a normal bolus with the variable bolus feature turned off
- Set a normal bolus with the variable bolus feature turned on
- Set a square wave bolus
- Set a dual wave bolus
- Review bolus history
- Suspend mode
- Programming a basal rate
- Programming basal delivery pattern
- Setting basal rate profiles in each delivery pattern
- Program a temporary basal rate
- Set a temporary basal rate
- Stop a temporary basal rate
- Personal events
- History
- Main menu
- Setup Pump
- Setup II
- Audio bolus
- Activating the audio bolus feature
- Set an audio bolus from the main menu bolus screen
- Variable bolus
- Refill
- Priming
- Diagnostic rate
- Initialize to factory defaults
- Download software
- Stop Pump
- Supervisor password
- Exit supervisor
- Personal Pump communicator messages
- Clinical history codes
- Clinical history PPC/Pump codes
- Audio bolus
- CHAPTER 4 Pump Implantation
Introduction
27
PPC buttons
Select:SEL
Activate:
The SEL button steps through each of the displays and
menus.
ACT
Activate:
The ACT button activates programming changes in the
Pump, new information to be entered into the PPC mem-
ory, and alarms to be turned off. As a safety check, ACT
must be pressed to complete any programming changes.
A single beep is heard after activating a change.
Up and Down
Arrows:
▲
▲▲
▲ or ▼
▼▼
▼
The ▲
▲▲
▲ or ▼
▼▼
▼ arrows allow changes in the screen set-
tings. Pressing
▲
▲▲
▲ once will find the next highest set-
ting, and pressing
▼
▼▼
▼ once will find the next lowest
setting. Holding down either button will rapidly scroll
through the list of preset values. Desired values can then
be programmed by pressing ACT.
Sound Icon
the Up Arrow
When the Audio Bolus feature is turned on, pressing
▲
▲▲
▲
allows programming an Audio Bolus.
Light Icon
the Down
Arrow:
From the main operating screen, pressing
▼
▼▼
▼ once will
turn on the backlight. The backlight allows the Pump to
be programmed in the dark. The backlight will turn off
automatically after four seconds.
Dmp9196021-011_c.book Page 27 Thursday, April 4, 2002 8:15 AM