Service manual

Page 8
MD 1772LB (B1770NSL/T)
MEDION
2-4 Display Power Management Signal (DPMS)
Note: These power-saving states exceed the Environmental Protection Agency (EPA) Energy Star
requirements and the Video Electronics Standard Association (VESA) for Display Power
Management Signal (DPMS) .
Table 2-3. Display Power Management Signal (DPMS)
State LED Color H-Sync V-Sync Power
Consumption
ON Green Pulse Pulse Normal
STANDBY Yellow No Pulse Pulse <15 watts
SUSPEND Yellow Pulse No Pulse <15 watts
OFF Amber No Pulse No Pulse <5 watts
2-6 TCO Version (Optional)
The monitor meets the TCO 92, NUTEK energy saving, electric and magnetic field requirements. Also it
is compliant with TCO 95/TCO 99 labelling scheme.
2-6-1TCO 92 Version (Optional)
The emission from magnetic and electric field must comply with the limits specified by the Swedish Board
for Measurement and Testing, commonly known as MPR 1990 recommendations. These limits are
summarized in the Table 2-4.
Table 2-4. TCO 92 Requirements
OCT/FLVOCT/FLE
dleiFcitengaMTn52Tn002
dleiFcirtcelEm/V1m/V01
egnaRycneuqerFzHk004~2zH0002~5
eulaVSMRSMR
ecnatsiDmc03mc03
citatsortcelE
laitnetoP
V005-/+V005-/+
The monitor is designed with selected CRT and carefully routed wires around CRT, make sure exactly the
same routing scheme is used when doing CRT replacement.