User guide
Chapter 6 - NioNode SNMP control
72 Version 1.7.2.0 March 27, 2015
.
Accessing exported NWare controls
Each exported NWare SNMP control has four variables associated with it: index, label, type
and value. Each variable can be accessed using a base OID to which an SNMP control index
(1-255) is appended. The SNMP control index is represented by x in the table below.
Index
The index of the exported control. Data type is integer.
1.3.6.1.4.1.24603.1.1.6.4.1.1.x
Label
A label for the control. This is blank, by default. It can
be set on the SNMP Exports tab of the NioNode device
in NWare. Data type is string.
1.3.6.1.4.1.24603.1.1.6.4.1.2.x
Type
The read/write status of the control value. Data type is
integer.
1.3.6.1.4.1.24603.1.1.6.4.1.3.x
1
Read-only
2
Read/write
Value
The control value as a string. When the value is read, it
will be returned along with the unit of measurement,
for example, 100dB or 300Hz. However, When the
value is written, you do not need to specify the unit of
measurement. Data type is string.
1.3.6.1.4.1.24603.1.1.6.4.1.4.x