User guide
Chapter 6 - NioNode SNMP control
70 Version 1.7.2.0 March 27, 2015
SNMP flyoffs will be added to the Flyoffs tab. You can wire NWare controls to the flyoffs
so the control values are automatically passed to the SNMP program, and the SNMP
program can send values back to the controls.
Wiring NWare controls to SNMP flyoffs
In order to pass values to the SNMP program and receive values from the program, you need to
wire NWare controls to SNMP flyoffs.
To wire NWare controls to SNMP flyoffs
1. Click the Flyoffs tab.
2. Expand the tree to show the flyoffs under SNMP.
3. Drag a flyoff over to the design page.
4. Create a master wiring node on the control you want to control using SNMP.
5. Wire the control to the SNMP flyoff.
6. Repeat steps 3-5 for the other controls you want to use in the SNMP program.
Labeling controls and setting read/write attributes
1. Open the NioNode block, and then click the SNMP Exports tab.
2. In the Label box next to each control, type a label that you want to use to refer to the
control.
3. If you want to allow the control value to be set, click the R/O (read-only) button to switch
it off.