User guide

External control user guide
March 27, 2015 Version 1.7.2.0 57
So, for example, setting a value with a user ID value tes would look like this Stes44., the result
will look like this Stes44.Vtes44.
Serial Control Value to Device Control Value Tables
This section shows some example mappings of serial control values to device control values.
An NWare knob control, for example, could have a range of 0 to 1, but the values returned by
the PASHA G (get) command would be in the hexadecimal range 0 - ff.
Note: The tables in this section do not show 0x at the start of the hex values, as it is not
returned as part of the PASHA message.
Control value to dB's of gain table: -100dB to +18.0dB type control
00: -100dB
01: -99.5dB
02: -99.1dB
03: -98.6dB
04: -98.1dB
05: -97.7dB
06: -97.2dB
07: -96.8dB
08: -96.3dB
09: -95.8dB
0a: -95.4dB
0b: -94.9dB
0c: -94.4dB
0d: -94.0dB
0e: -93.5dB
0f: -93.1dB
10: -92.6dB
11: -92.1dB
12: -91.7dB
13: -91.2dB
14: -90.7dB
15: -90.3dB
16: -89.8dB
17: -89.4dB
18: -89.9dB
19: -88.4dB
1a: -88.0dB
1b: -87.5dB
1c: -87.0dB
1d: -86.6dB
1e: -86.1dB
1f: -85.7dB
20: -85.2dB
21: -84.7dB
22: -84.3dB
23: -83.8dB
24: -83.3dB
25: -82.9dB
26: -82.4dB
27: -82.0dB
28: -81.5dB
29: -81.0dB
2a: -80.6dB
2b: -80.1dB
2c: -79.6dB
2d: -79.2dB
2e: -78.7dB
2f: -78.3dB
30: -77.8dB
31: -77.3dB
32: -76.9dB
33: -76.4dB
34: -75.9dB
35: -75.5dB
36: -75.0dB
37: -74.5dB
38: -74.1dB
39: -73.6dB
3a: -73.2dB
3b: -72.7dB
3c: -72.2dB
3d: -71.8dB
3e: -71.3dB
3f: -70.8dB
40: -70.4dB
41: -69.9dB
42: -69.5dB
43: 69.0-dB
44: -68.5dB
45: -68.1dB
46: -67.6dB
47: -67.1dB