User guide
Chapter 3 - RATC2
36 Version 1.7.2.0 March 27, 2015
In the response, the first token after the alias name is the current value expressed in the units
appropriate to that particular control. In the response, the second token after the Control Alias
name is the current value of the alias expressed as a percentage of the maximum value
expressed as a decimal value between 0 and 1. This can be thought of as a physical knob
position - in this example, the 0.615 (61.5%) knob position corresponds to -3.4dB, and a 1.000
(100%) knob position will correspond to +12dB.
Possible Error Messages
\aBadArgumentCount\r\n
\anotLoggedIn\r\n
\aUnlistedControl "AliasName"\r\n
\aOverflow\r\n