User manual

KNR-p4Px4 KNR-p16Px8 User Manual
132
Figure 9. 14 More Settings Interface
3. Enter Alarm Host IP and Alarm Host Port in the text fields.
The Alarm Host IP refers to the IP address of the remote PC on which the Network Video Surveillance
Software (e.g.,CMS) is installed, and the Alarm Host Port must be the same as the alarm monitoring port
configured in the software.
Figure 9. 15 Configure Alarm Host
4. Click Apply button to save and exit the interface.
9.2.6 Configuring Multicast
Purpose:
The multicast can be configured to realize live view for more than 64 cameras through network for NR300 series NVR.
A multicast address spans the Class-D IP range of 224.0.0.0 to239.255.255.255. It is recommended to use the IP
address ranging from 239.252.0.0 to 239.255.255.255.
Steps:
1. Enter the Network Settings interface.
Menu >Configuration> Network
2. Select the More Settings tab to enter the More Settings interface, as shown in Figure 9. 14.
3. Set Multicast IP, as shown in Figure 9. 16. When adding a device to the Network Video Surveillance Software,
the multicast address must be the same as the NVR’s multicast IP.
Figure 9. 16 Configure Multicast
4. Click Apply button to save and exit the interface.
Note: The multicast function should be supported by the network switch to which the NVR is connected.