Specifications

80 Hardware Description and Reference for Avaya Communication Manager
Electromagnetic-compatibility (EMC) standards and approvals
The following table lists the standards and approvals for product electromagnetic compatibility
(EMC).
Data rack mounting and media gateway floor loading
The S8700-series Media Server configuration includes the following hardware components:
Two S8700-series Media Servers
Ethernet Switch
Modem
Two UPS units
19-Inch (48.3 centimeter) rack
The customer provides a data rack. This rack holds equipment that is not necessarily specified
or provided by Avaya. The footprint of the data rack is 19 inches (48.3 cm) by 21 inches (53.3
cm).
S8700-series Media Server
The S8700-series Media Servers are designed for mounting in an open 19-inch (48.3
centimeters) data rack. The S8700-series Media Servers weigh approximately 25 pounds
(11.33 kilograms).
Country EMC standards and approvals
US FCC 47 CFR Parts 2 and 15, Verified Class A Limit
Canada IC ICES-003 Class A Limit
Europe EMC Directive, 89/336/EEC
EN55022, Class A Limit, Radiated and Conducted Emissions
EN55024, Immunity Standard for Information Technology Equipment
EN61000-3-2 Harmonic Currents
EN61000-3-3 Voltage Flicker
Australia and
New Zealand
C-Tic: AS/NZS 3548, Class A Limit
Japan VCCI Class A ITE (CISPR 22, Class A Limit)
IEC 61000-3-2, Harmonic Currents
Taiwan BSMI Class A (CISPR 222)
Russia Gost Approval
International CISPR 22, Class A Limit