Specifications
60 Hardware Description and Reference for Avaya Communication Manager
Note:
Note: Some values are shown at maximum configuration. Avaya values are slightly
lower then maximum.
Type Description
Acoustical Noise Emissions
● Sound power, idling: 6.5 bel maximum
● Sound power, operating: 6.5 bel maximum
Environment: Air Temperature Server on:
● 50.0 °F to 95.0 °F (10 °C to 35 °C)
● Altitude: 0 to 914 m (2998.7 ft)
Server off:
● -104 °F to 140 °F (-40 °C to 60 °C)
● Maximum altitude: 2133 m (6998.0 ft)
Environment: Humidity Server on:
● 8% to 80%
Server off:
● 8% to 80%
Heat Output BTU output per hour (approximate):
● Maximum configuration: 512 BTU (150 watts)
Electrical Input
● Sine-wave input (47-63 Hz) required
● Input voltage low range:
- Minimum: 100 V ac
- Maximum: 127 V ac
● Input voltage high range:
- Minimum: 200 V ac
- Maximum: 240 V ac
● Input kilovolt-amperes (kVA) (approximate):
- Minimum: 0.0870 kVA
- Maximum: 0.150 kVA
● Receptacle U.S.: XXXX 87=NEMA 5-15
● Circuit breaker: XXXX 87=15 amp
● Pole: XXXX 87=1
● Amp Draw: XXXX 87=3