Specifications
Avaya Wireless Solutions
372 Hardware Description and Reference for Avaya Communication Manager
Specifications
Table 30 shows the site requirements of the W310 WLAN Gateway.
A readily accessible listed safety-approved protective device with a 15A rating must be
incorporated in series with building installation AC power.
Table 30: W310 specifications
Description Value
Ambient working temperature 0-40°C (32 - 104°F)
Humidity 5-95% relative humidity (not condensing)
DC input voltage 50 to 57 VDC
DC input current 8 A
DC isolation 1500 V RMS with respect to protective ground
AC input voltage 100 to 240 VAC, 50/60 Hz
AC input current 4 A
AC power dissipation 400 W maximum