Specifications

122 Hardware Description and Reference for Avaya Communication Manager
Specifications
Site requirements
The following table shows you the site requirements of the G350 Media Gateway.
Power cord specifications
Following are specifications for power cords suitable for use with the G250:
For North America: The cordset must be UL Listed/CSA Certified, 16 AWG, 3-conductor (3rd
wire ground), type SJT. One end is to be terminated to an IEC 60320, sheet C13 type connector
rated 10A, 250V. The other end terminates to either a NEMA 5-15P attachment plug for nominal
125V applications or a NEMA 6-15P attachment plug for nominal 250V applications.
For Outside North America: The cord must be VDE Certified or Harmonized (HAR), rated
250V, 3- conductor (3rd wire ground), 1.0 mm2 minimum conductor size. The cord terminates at
T1/E1 port (G250-DS1) For T1, this port is capable of supporting inband
signalling across all 24 channels (supports a
maximum bandwidth of 1.536 Mbps).
For E1, this port is capable of supporting R2MFC
signalling across all 30 channels (supports a
maximum bandwidth of 1.92 Mbps).
PRI ports (G250-DS1) The PRI ports are capable of supporting PRI
signalling for 23 or 30 bearer channels. NFAS
signalling is not supported.
Table 9: Fixed ports and buttons on the G250 front panel (continued)
Port Description
3 of 3
Description Value
Ambient working temperature 32-104 °F (0-40 °C)
Operation altitude up to 10,000 ft. (3048 m)
Front clearance 12 in. (30 cm.)
Rear clearance 18 in. (45 cm.)
Humidity 95% non-condensing relative humidity
Power rating 100-240 V~, 50-60 Hz, 2.2 A Max