User's Manual

Medeco Hybrid User Guide
7 of 16
4.6 Key Validation Dates
Each user key in the database is given a start date and end date. If the current
date is within that window then the group parameters & permissions will be
checked. Otherwise the key will be rejected. Groups 1-9 are all subject to
validation date checking. The Master Key (Group 0) is not.
4.7 Group Codes
Each Group Number 2-9 has an associated Group Code. (Group Numbers 0 & 1
do not have an associated Group Code). The Group Code indicates whether or
not Holidays should be checked before access is granted.
4.8 Daily Time Zone Schedules
Each Group Number 2-9 has 4 time zones per day of the week during which
access may be granted. The time zones are check last, and apply even if a key
has passed all validation checks.
Each time zone is specified by a Start time and an End time.
4.8.1 Start Hours and End Hours entries are (0-23)
Start Min and End Min entries are (0-59)
Day of the week proceeds from Sunday to Saturday. (0-6)
5 Access Control Operation
Each key ID stored in the database has an associated group number (0-9) and a
start and end validation date.
When a key is read by the Hybrid reader, a decision to grant or deny access is
made. Below is a brief overview of this decision process. (assumes the key is a
user key, not the master key.)
Find the key in the database
Check the validation dates
Check the Group #, otherwise reject the key.
o If the Group# = 0 & tag is not the master then reject the tag.
(Except for the master tag)
o If the Group# = 1 then accept the tag and unlock 24/7.
o If the Group# = 2-9
check holidays if the associated Group Code is enabled
Check 4 Daily Time zones for the group
5.1 LED Annunciations
The following table describes the annunciations for the Hybrid reader. All LED
signals will be flashing. The rate and duration are noted in the comments
(Number of Flashes, On Time (ms), off Time (ms)).