User's Manual
Medeco Hybrid User Guide
14 of 16
6.4.3 Rotate cam on back of Hybrid cylinder to home position – This removes
the cylinder from the shipping (unlocked) position and mechanically “arms”
the Hybrid cylinder. A properly bitted key must now be used to operate
lock cylinder.
6.4.4 Install (screw) the Hybrid cylinder into the lockset. Check for operation
with the lockset using the User key to operate the cylinder mechanically.
Adjust the cylinder as necessary for door thickness, cam engagement, etc.
6.4.5 When cylinder adjustments are complete, tighten set screw in lockset to
secure cylinder in place.
6.4.6 Install base plate and lock ring to secure lock cylinder to door. Install
spacers as required for thin door applications.
6.4.7 Place cylinder in locked position and remove the User key. User key is no
longer needed until Hybrid install is completed.
6.4.8 Ensure the battery is removed from the MCU unit.
6.4.9 Connect the cable from the cylinder to the back of the MCU unit.
6.4.10 Locate and install the MCU onto the base plate using four screws. Care
must be taken to ensure the interconnect cable is routed properly behind
MCU and is not damaged.
6.4.11 Install the battery into the MCU
MCU will power up and flash the LED red, yellow, green - one sequence.
The MCU will power up in tamper condition.
The LCU will power up and “arm” the electronic blocking mechanism (mechanical
key alone will no longer operate lock)
6.4.12 Install the MCU outer cover
The tamper switch will be reset