An ASSA ABLOY Group Company Hybrid e-Cylinder User Guide Version 2.
Medeco Hybrid User Guide Table of Contents 1 2 3 4 Introduction ....................................................................................................3 Design Description – Hybrid Main Control Unit (MCU) ..................................4 Design Description – Hybrid Lock Cylinder (LCU) .........................................5 Functional Description ...................................................................................5 4.1 IR Communications ...................................
Medeco Hybrid User Guide 1 Introduction The Medeco/HID 125 kHz E-Cylinder is a battery operated RFID enabled electromechanical lock (Figure 1). The unit as a whole is designed to be self-contained (no external wire or communication connections) and operates to secure a door or entry portal.
Medeco Hybrid User Guide 2 Design Description – Hybrid Main Control Unit (MCU) The Hybrid MCU consists of the following components illustrated in Figures 2 & 3. These items include: Internal Housing with electronic module - MCU External Housing cover Rubber Insert LED Lens Anti-tamper Contact Optional Spacer (thin) Optional Spacer (thick) Figure 2: The primary subsystems comprising the Medeco/HID 125 kHz E-Cylinder.
Medeco Hybrid User Guide 3 Design Description – Hybrid Lock Cylinder (LCU) The Hybrid lock cylinder consists of the following components illustrated in Figure 4.
Medeco Hybrid User Guide • • • 4.1 3-level low battery alarm (alarm condition may be reset using a Master key or using the IR interface) Access Control system for controlling access based on user groups, valid entry times/dates. Tamper monitoring feature with temporary reader disable IR Communications The Hybrid MCU contains an IR communications port that allows programming of the unit with user keys, schedules, holidays etc.
Medeco Hybrid User Guide 4.6 Key Validation Dates Each user key in the database is given a start date and end date. If the current date is within that window then the group parameters & permissions will be checked. Otherwise the key will be rejected. Groups 1-9 are all subject to validation date checking. The Master Key (Group 0) is not. 4.7 Group Codes Each Group Number 2-9 has an associated Group Code. (Group Numbers 0 & 1 do not have an associated Group Code).
Medeco Hybrid User Guide Table 1.
Medeco Hybrid User Guide value, the Hybrid MCU will be shut down to a minimum power state with no keydetection. 5.3 Tamper Alarm The Hybrid MCU contains tamper circuitry that detects if the outer cover is removed or power is lost for any reason. If the tamper condition is detected a transaction will be stored. A tamper condition will cause the Hybrid MCU to reject all user keys until reset by presentation of the Master key.
Medeco Hybrid User Guide 6.2.3 Rotate cam on back of Hybrid cylinder to home (locked) position – This removes the cylinder from the shipping (unlocked) position and mechanically “arms” the Hybrid cylinder. A properly bitted key must now be used to operate the lock cylinder. 6.2.4 Install (screw) the Hybrid cylinder into the lockset. Check for operation with the lockset using the User key to operate the cylinder mechanically. Adjust the cylinder as necessary for door thickness, cam engagement, etc. 6.2.
Medeco Hybrid User Guide The MCU will start to search (ping) for a key At this point: MCU is still in tamper mode MCU has no master key identified and stored MCU and LCU are not registered to each other MCU and LCU are not authorized with each other MCU clock is not set MCU is not programmed with a key list, schedules, etc. 6.2.
Medeco Hybrid User Guide (The MCU will flash the LED red if the IR communications session times out prior to completing the communications session.) The Hybrid unit is now functional and ready for use 6.2.19 Present the User key to test the function of Hybrid unit with the lockset 6.3 Procedure for programming an MCU prior to installation at door. Note: LCU is not connected or utilized in the advance programming of the MCU.
Medeco Hybrid User Guide The MCU flashes the LED green, red, green to indicate the master key was accepted but no LCU was found. MCU resets the tamper condition MCU turns on the IR communications port - The MCU will flash the LED red when the IR communications session times out. 6.3.4 Program the Hybrid unit with the PDA – PDA should be loaded with key list (including User key used for installation) 6.3.5 Present the PDA to the MCU – IR port on PDA must be active 6.3.
Medeco Hybrid User Guide 6.4.3 Rotate cam on back of Hybrid cylinder to home position – This removes the cylinder from the shipping (unlocked) position and mechanically “arms” the Hybrid cylinder. A properly bitted key must now be used to operate lock cylinder. 6.4.4 Install (screw) the Hybrid cylinder into the lockset. Check for operation with the lockset using the User key to operate the cylinder mechanically. Adjust the cylinder as necessary for door thickness, cam engagement, etc. 6.4.
Medeco Hybrid User Guide The MCU will start to search (ping) for a key At this point: MCU is still in tamper mode MCU has a master key previously identified and stored MCU and LCU are not registered to each other MCU and LCU are not authorized with each other MCU clock is not set MCU already programmed with a key list, schedules, etc. 6.4.13 Register the MCU and LCU, set clock and reset tamper with PDA 6.4.14 Present the PDA to the MCU – IR port on PDA must be active 6.4.
Medeco Hybrid User Guide 7 Notifications This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.