Installation Guide
12/04/07
Revision 1.0
1 of 6
Medeco HYBRID eCylinder
Installation Procedures – Mortise Application
1. What is required:
Hybrid cylinder kit
Hybrid Cylinder (LCU) with proper cam
MCU reader unit
MCU outer cover
MCU spacers
Base plate
Lock Ring
MCU mounting screws
Battery
User key with correct mechanical keyway and cut
Hybrid 125KHz Prox key head
PDA programming device
Programmed from the Hybrid Manager software
Including access rights for the User Key
The functionality to set the MCU clock
Hybrid Manager Software
2. Installation procedure when MCU is programmed at the door
2.1 Remove mechanical cylinder from lockset. (if applicable)
2.2 Verify proper cam on Hybrid cylinder for lockset.
2.3 Rotate cam on back of Hybrid cylinder to home (locked) position – This
removes the cylinder from the shipping (unlocked) position and mechanically
“arms” the Hybrid cylinder. A properly bitted key must now be used to operate
the lock cylinder.
2.4 Install (screw) the Hybrid cylinder into the lockset. Check for operation with
the lockset using the User key to operate the cylinder mechanically. Adjust the
cylinder as necessary for door thickness, cam engagement, etc.
2.5 When cylinder adjustments are complete, tighten set screw in lockset to
secure cylinder in place.