SDS
Mechanic in a Bottle 
Conforms to OSHA CFR 29 1910.1200 and aligns to the United Nations Globally Harmonized System 
Conforms to The United Nations Regulation Globally Harmonized System 
Page 7 of 11 
Section 11- Toxicological Information 
11.1 
Product Name 
Results 
Species 
Dose 
Exposure 
Blend of Medium Chain 
Triglycerides, saturated fatty acid 
and modified glycol ether 
Oral 
LD50 
Rat 
554.9 mg/kg 
None Listed 
Blend of Medium Chain 
Triglycerides, saturated fatty acid 
and modified glycol ether 
Inhalation 
LC50 
Rat 
3.358mg/l 
None Listed 
Blend of Medium Chain 
Triglycerides, saturated fatty acid 
and modified glycol ether 
Dermal 
LC50 
Rabbit 
524.9 mg/kg 
None Listed 
11.1.1 OECD Guideline Test results found in the European Chemical Agency Data Base shows that components 
of this product to cause Oral Toxicity. 
11.11.2 OECD Guideline Test results found in the European Chemical Agency Data Base shows that mist of 
components of this product to cause Inhalation Toxicity. 
11.11.3 OECD Guideline Test results found in the European Chemical Agency Data Base shows that components 
of this product to cause Dermal Toxicity. 
11.2 Route of Entry: Inhalation, Ingestion, Absorption, Skin and/or Eye Contact 
11.3 Aspiration Hazard: European Chemical Agency Data Base shows that components of this product may be 
fatal if swallowed and enters airways. However, a test of this product shows that it is an aspiration hazard. 
11.4 Mutagenicity: European Chemical Agency Data Base show no components of this product to cause 
genetic defects. 
11.5 Skin Corrosion/Irritation: OECD Guideline Tests results found in the European Chemical Agency Data 
Base shows that components of this product to cause skin irritation. Repeated exposure may cause skin dryness 
or cracking.   
11.6 Serious Eye Damage/Irritation: OECD Guideline Tests results found in the European Chemical Agency 
Data Base shows that components of this product to cause serious eye irritation. 
11.7 Specific Target Organ Toxicity (Single Exposure): European Chemical Agency Data Base shows that no 
components of this product may cause damage central nervous system (CNS). Human exposure above 200 ppm 
can be expected to cause narcosis, damage to the kidney and liver and present an abnormal blood picture 
showing erythropenia, reticulocytosis, granulocytosis, leukocytosis, and would be likely to cause fragility of 
erythrocytes and hematuria. 
11.8 Reproductive toxicity: European Chemical Agency Data Base show no components of this product to 
cause damage to fertility or the unborn child. 
11.9 Skin Sensitisation OECD Guideline Tests results found in the European Chemical Agency Data Base 
show no components of this product to cause skin sensitively. 










