result, if the conditions to detect the small movements are met. Please see the
code 12321< (Backlash compensation calibration) for more details.
Rotator 2 Set the upper rotator in use by selecting an option from the list, or
using the following codes: 23131< for E1, 23132< for E2, and 23121< for P1. The
AUTO option enables the automatic detection of the rotator type for the upper
rotator.
Inverted for upper rotator The same as Inverted for lower rotator.
Backlash 2, for upper rotator The same as Backlash for lower rotator. The
backlash compensation calibration code is 123212<.
Buzzer PWM and Start Page
Buzzer PWM values Range from 1 to 255, and do not necessarily refer to the
sound loudness. We recommend that you try a few values to find your preferred
value.
Start Page Can be New, Row, or Ring, and can also be set on these pages.
IR Settings and more
Enable i2c on Aux Port Upcoming feature.
Use New Shutter Confirmation It will be used in both shutter confirmation and
test of shutter confirmation (see the Shutter CONF. TEST option in the Cong
Menu). If the test fails, please perform the test again with this option disabled.
Shutter Confirmation Time Out (sec) The maximum time MECHA waits for the
shutter confirmation to occur.