Specifications

Indicator Display
>0<- Scale is zeroed and gross weight is 0, tare is 0.
Net - Display reading is net weight; tare is not 0.
lb, kg, oz - Unit of measure.
Hold - Scale is in dynamic weighing mode.
- Hold flashes - actual fluctuating weight is displayed.
- Hold does not flash - locked weight is displayed.
Function Keys
KEY MODE DEFINITION
<3 seconds Send output data via the USB port
Weighing mode
>3 seconds Enter or exits HOLD mode
PRINT/HOLD
Setup or Calibration mode Shift the flashing data entry position from right to left
Weighing mode Select weight unit of measure
UNIT
Setup/Calibration mode Increase the digit in the flashing data entry position by 1
Weighing mode Tare the weight
TARE
Setup or Calibration mode Confirm the input data and forwards to next step
<3 seconds Zero the platform weight
Weighing mode
>3 seconds Power off the scale
ON/OFF/ZERO
Setup or Calibration mode Exit to normal weighing mode
ON/OFF/ZERO
+UNIT
Weighing mode
(more than 3 seconds)
Enter user parameter setup mode
ON/OFF/ZERO
+TARE
Weighing mode
(more than 3 seconds)
Enter calibration mode
3. OPERATIONS
Normal Weighing Mode
1. Power on the scale by pressing the ZERO/ON/OFF key.
2. When the display stabilizes, but it doesn’t show zero, press ZERO/ON/OFF to set new zero point.
3. Place objects on the scale platform and read the weight on the indicator.
Note: Objects should be placed at the center of the platform. Corner or side loading heavy objects may risk
overloading an individual load cell and damage the scale.
Yes No No
PS102 www.measuretek.net .3