Datasheet

48~57.6V
250mVp-p
48V
±0.5%
±0.5%
±1.0%
95%
59 ~ 66V
UHP-750-48
15.7A
753.6W
750W Slim Type with PFC Switching Supply
VOLTAGE ADJ. RANGE
105~125% rated output power
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
DIMENSION
OTHERS
NOTE
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
1000ms, 50ms/230VAC 1000ms,50ms/115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
Cold start 20A/115VAC 40A/230VAC
-30 ~ +70 (Refer to “Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing
±℃ )0.03%/ (0 ~ 50
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
279.97 104.86K hrs min. Telcordia SR-332 (Bellcore); K hrs min. MIL-HDBK-217F (25 )
PF 0.95/230VAC PF 0.99/115VAC at full load≥≥
12ms/230VAC 12ms/115VAC
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : line regulation and load regulation.includes set up tolerance,
4. Derating may be needed under low input voltages. Please check the for more details.derating curve
5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
6. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
ENVIRONMENT
PROTECTION
237*100*41mm (L*W*H)
Protection type: Shut down O/P voltage, re-power on to recover
Protection type: Shut down O/P voltage, recovers automatically after temperature goes down
7.5A/115VAC 3.8A/230VAC
RATED POWER
(convection)
1.4kg; 10pcs/15kg/0.8CUFT
47 ~ 63Hz
Protection type: Hiccup mode, recovers automatically after fault condition is removed
FUNCTION
DC-OK SIGNAL
Contact rating(max.): 30Vdc/1A resistive load
SAFETY STANDARDS
SAFETY &
EMC
(Note.5)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P: 3.75KVAC I/P-FG: 2KVAC O/P-FG: 1.25KVAC
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25 / 70%RH
UL62368-1,TUV EN62368-1, approved; design refer to EN61558-1, EN60335-1EAC TP TC 004
<0.75mA / 240VAC
93.5%
12~14.4V
±0.5%
±0.5%
±1.0%
150mVp-p
12V
14.5 ~ 16V
UHP-750-12
60A
720W
36~43.2V
250mVp-p
36V
±0.5%
±0.5%
±1.0%
95%
43.5 ~ 49V
UHP-750-36
20.9A
752.4W
UHP-750 series
MTBF
PACKING
24~28.8V
200mVp-p
±0.5%
±0.5%
±1.0%
95%
29 ~ 33V
UHP-750-24
751.2W
24V
31.3A
EMC IMMUNITY
EMC EMISSION
Parameter
Parameter
ESD
Radiated
EFT / Burst
Surge
Conducted
Magnetic Field
Voltage Dips and Interruptions
Conducted
Radiated
Harmonic Current
Voltage Flicker
EN55024 , EN61000-6-2
Standard
Standard
EN55032 (CISPR32)
EN55032 (CISPR32)
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-6-2
EN61000-4-6
EN61000-4-8
EN61000-4-11
Test Level / Note
Test Level / Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 3
Level 3
2KV/Line-Line 4KV/Line-Earth
Level 3
Level 4
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Class B
Class B
Class A
-----
File Name:UHP-750-SPEC 2019-07-26