Datasheet
UHP-200A series
200W Single Output with PFC Function
UHP-200A-4.2
UHP-200A-5
UHP-200A-4.5
File Name:UHP-200A-SPEC 2018-09-13
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Transient response meansure shall be made with 10% load at least.
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
8. Warnning: This equipment is compliant with Class A of CISPR 32. In a residential environment may cause radio interference.
±2.5%
±0.5%
±4.0%
±2.5%
±0.5%
±4.0%
±2.5%
±0.5%
±4.0%
4.0~4.4V 4.3~4.7V 4.7~5.3V
200mVp-p 200mVp-p 200mVp-p
168W 180W 200W
0~40A 0~40A 0~40A
40A 40A 40A
5V
4.5V
4.2V
2000ms, 200ms/230VAC at full load, 3000ms, 200ms/115VAC at 80% load
10ms/230VAC 10ms/115VAC
PSU Turns on:DC ok; PSU turns off:DC fail
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF 0.97/115VAC PF 0.95/230VAC at full load≥≥
88% 88% 88.5%
2.4A/115VAC 1.2A/230VAC
Cold start 85A/230VAC
<1.0mA / 240VAC
110~140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
4.6 ~ 6V
5 ~ 6.4V
5.6 ~ 7.1V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut down O/P voltage, recovers automatically after fault condition is removed
-30 ~ +70 (Refer to “OUTPUT LOAD vs TEMPERATURE")℃
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃ ℃)0.03%/ (0 ~ 50
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1,TUV EN60950-1,CCC GB4943, EAC TP TC 004 approved
I/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25 / 70%RH℃
Compliance to EN55032 (CISPR32),GB9254,Class A, EN61000-3-2,-3,GB17625.1,EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024, light industry level (surge 4KV),EAC TP TC 020
204K hrs min. MIL-HDBK-217F (25 )℃
167*55*26mm (L*W*H)
0.42kg; 20pcs/ 11.4kg/0.76CUFT
DIMENSION
OTHERS
NOTE
MTBF
PACKING
SAFETY &
EMC
(Note.5)
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC IMMUNITY
EMC EMISSION Note.8
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
OVER TEMPERATURE
OVERLOAD
OVER VOLTAGE
PROTECTION
SHORT CIRCUIT
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR
(Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT
(Typ.)
LEAKAGE CURRENT
AC CURRENT
(Typ.)
VOLTAGE ADJ. RANGE
DC VOLTAGE
RATED CURRENT
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME
(Typ.)
VOLTAGE TOLERANCE
Note.3
RATED POWER(convection)
CURRENT RANGE
RIPPLE & NOISE
(max.) Note.2
DC OK FUNCTION
SPECIFICATION
MODEL