Datasheet

SPECIFICATION
40WAC-DC High Reliability Slim Wall-mountedAdaptor
SGA40E series
File Name:SGA40E-SPEC 2015-05-05
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.)
Note.3
OUTPUT
SETUP, RISE, HOLD UP TIME
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 8)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
LIFE
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V 9V 12V 15V 18V 24V 48V
SGA40E05 SGA40E09 SGA40E12 SGA40E15 SGA40E18 SGA40E24 SGA40E48
SGA40E05-P1J SGA40E09-P1J SGA40E12-P1J SGA40E15-P1J SGA40E18-P1J SGA40E24-P1J SGA40E48-P1J
5A 4.44A 3.33A 2.66A 2.22A 1.67A 0.84A
0 ~ 5A 0 ~ 4.44A
0 ~ 3.33A
0 ~ 2.66A 0 ~ 2.22A 0 ~ 1.67A
120mVp-p 120mVp-p 120mVp-p 120mVp-p 120mVp-p 150mVp-p 150mVp-p
VOLTAGE TOLERANCE
Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0% ±5.0% ±3.0% ±2.0% ±2.0% ±2.0% ±2.0%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0% ±3.0% ±2.0% ±2.0% ±2.0% ±2.0%
90 ~ 264VAC
47 ~ 63Hz
1A / 115VAC 0.5A / 230VAC
40A / 115VAC 70A / 230VAC
0.25mA / 240VAC
TUV EN60950-1 approved
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
3 years : 100% load 40 , 12hours / day
400Khrs min. MIL-HDBK-217F(25 )
-20 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
±℃0.03% / (0 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
75.5*32*47.5mm (L*W*H)
165g ; 60pcs / 13kg / CARTON
CONNECTOR
PLUG
CABLE
25W 40W 40W 40W 40W 40W 40W
0 ~ 0.84A
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load
7.Derating may be needed under low input voltages. Please check the static characteristics for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
OVERLOAD
OVER VOLTAGE
110 ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 140% rated output voltage
Protection type : Clamp by zener diode, output short
Compliance to EN55022 class B, EN61000-3-2,3
500ms, 100ms, 12ms/230VAC 500ms, 100ms, 12ms/115VAC at full load
83% 86% 86.5% 86.5% 87% 88% 89%
EMC EMISSION
See page 3 ; Other type available by customer requested
See page 3 ; Other type available by customer requested
Compliance to EN61000-4,-2,3,4,5,6,8,11,
light industry level, criteria A
EMC IMMUNITY
VOLTAGE RANGE
Note.7