Datasheet

SPECIFICATION
SD-100B-5 SD-100C-5 SD-100D-5 SD-100C-12 SD-100D-12 SD-100C-24 SD-100D-24
(for D type only)
SD-100B-12 SD-100B-24
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME(Typ.)
VOLTAGERANGE
EFFICIENCY (Typ.)
INPUT
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
DCCURRENT (Typ.)
5V 12V 24V
20A 8.5A 4.2A
0~20A 0~8.5A 0~4.2A
100W 102W 100.8W
100mVp-p 120mVp-p 150mVp-p
2.0% 1.0% 1.0%
4.5~5.5VDC 11~16VDC 23~30VDC
0.5%
0.5%
0.3%
0.3%
0.2%
0.2%
2s,50ms(onlyDmode)atfullload
20ms(onlyDmode)atfullload
B:19~36VDCC:36~72VDCD:72~144VDCor85~132VAC
74%
4.8A/24V 4.8A/24V 4.8A/24V
D:18A/96VDC
<0.75mA/120VAC(SD-100D)
75% 76% 75%
2.4A/48V 2.4A/48V2.4A/48V
77% 80% 78% 81% 83%
1.8A/96V 1.8A/96V 1.8A/96V
105~135% ratedoutputpower
5.75~6.75V/10%load 16.8~20V/10%load 31.5~37.5V/10%load
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
CompliancetoEN55022(CISPR22)ClassB
IEC60950-1CBapprovedby TUV(forDtypeonly)
Complianceto ightEN61000-4-2,3,4,6,8,l industrylevel,criteria A
-10~+60
(Referto"DeratingCurve")
20~90%RHnon-condensing
-20~+85 ,10~95%RH
0.03%/ (0~50
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
356.7Khrsmin.(SD-100B)355.5Khrsmin.(SD-100C)341.9KHrsmin.(SD-100D)MIL-HDBK-217F(25 )
199*98*38mm(L*W*H)
0.65Kg;20pcs/13.8Kg/0.8CUFT
FileName:SD-100-SPEC2011-08-23
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
100WSingleOutputDC-DCConverter
2:1 wide input range
Protections: Short circuit / Overload / Over voltage
1500VAC I/O isolation
Built-in EMI filter, low ripple noise
100% full load burn-in test
Fixed switching frequency at 83KHz
24V and 48V input voltage design refer to LVD
Low cost
High reliability
2 years warranty
Features :
SD-100 se ri es
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
1. All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:1.5KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
EMCIMMUNITY
EMCEMISSION