Data Sheet
SPECIFICATION
MODEL SCP-35-12
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
PEAK 5S
Note.6
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
Note.4
LOAD REGULATION Note.5
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
FUNCTION
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
EMC IMMUNITY
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
13.8V
2.6A
0 ~ 2.6A
3.1A
35.9W
120mVp-p
+15,-5%
±2.0%
±1.0%
±2.0%
500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load
50ms/230VAC 16ms/115VAC at full load
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
16.6 ~ 19.3V
83%
0.75A/115VAC 0.5 A/230VAC
COLD START 45A
<2mA / 240VAC
3.1 ~ 4.2A rated output power
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,3, EAC TP TC 020
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, light industry level, criteria A, EAC TP TC 020
-20 ~ +60 (Refer to output load derating curve)℃
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃℃0.05% / (0 ~ 45 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
523.3Khrs min. MIL-HDBK-217F (25 )℃
File Name:SCP-35-SPEC 2018-01-12
99*97*36mm (L*W*H)
0.37Kg; 45pcs/17.7Kg/1CUFT
35W Single Output Switching Power Supply
SCP-35 series
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
ENVIRONMENT
SAFETY &
EMC
(Note 6)
PROTECTION
EMC EMISSION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. 33% Duty cycle maximum within every 15 seconds. Average output power should not exceed the rated power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
8. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
(As available on http://www.meanwell.com)
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
Universal AC input/Full range
Protections: Short circuit / Overload / Over voltage / Battery
polarity protections (by fuse)
Built-in temperature compensation function
Output voltage detection signal
Cooling by free air convection
LED indicator for power on
No load power consumption <0.75W
Suitable for installation in metallic or non-metallic system enclosure
100% full load burn-in test
2 years warranty
■
Features :
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
UL60950-1, CB(IEC60950-1) approved
, EAC TP TC 004
1.4A
27.6V
1.7A
0 ~ 1.4A
38.6W
200mVp-p
±1.0%
±1.0%
±1.0%
86%
1.7 ~ 2.3A rated output power
33.1 ~ 38.5V
SCP-35-24
+15,-5%
OUTPUT VOLTAGE SENSOR
TEMP. COMPENSATION
By NTC (not provide with the power supply)
L=output voltage +0.2 ~ 0.7V(AC OK); L=0V(AC Fail)