Datasheet
Protection type : Hiccup mode, recovers automatically after fault condition is removed
SPECIFICATION
MODEL RT-50A RT-50B RT-50C RT-50D
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION Note.4
LOAD REGULATION Note.5
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
5V 12V
CH2
-5V
CH3
12V
CH2
-12V
CH3
5V
CH1
5V
CH1
15V
CH2
24V
CH2
-15V
CH3
12V
CH3
5V
CH1
4A 2A 0.5A 2A 0.5A 4A 3A1.5A 1A0.5A 1A4A
0.5 ~ 5A 0.2 ~ 2.5A 0.1 ~ 1A 0.2 ~ 2.5A 0.1 ~ 1A 0.5 ~ 5A 0.5 ~ 5A0.2 ~ 2A 0.2 ~ 1.5A0.1 ~ 1A 0.1 ~ 1A0.5 ~ 5A
46.5W 50W 50W 51W
80mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p 80mVp-p 80mVp-p120mVp-p 150mVp-p120mVp-p 120mVp-p80mVp-p
CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V
±2.0% ±6.0% ±3.0% ±3.0% ±3.0%±6.0% ±2.0% ±2.0%+8,-4% + 8,-4% ±6.0%±2.0%
±0.5% ±1.5% ±0.5% ±0.5% ±0.5%±1.5% ±0.5% ±0.5%±1.5% ±2.0%±2.0%±0.5%
±1.0% ±3.0% ±1.0% ±1.0% ±1.0%±3.0% ±1.0% ±1.0%±3.0% ±3.0% ±4.0%±1.0%
500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
60ms/230VAC 10ms/115VAC at full load
88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
47 ~ 63Hz
77% 78% 80%77%
CH1: 5.75 ~ 6.75V
1.3A/115VAC 0.8A/230VAC
COLD START 36A/230VAC
<2mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
UL60950-1, TUV EN60950-1 approved
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
-25 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 50℃)on +5V output
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
169.2Khrs min. MIL-HDBK-217F (25℃)
99*97*36mm (L*W*H)
File Name:RT-50-SPEC 2013-12-17
0.41Kg; 45pcs/19.5Kg/0.9CUFT
50W Triple Output Switching Power Supply
RT-50 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
ENVIRONMENT
SAFETY &
EMC
(Note 6)
PROTECTION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
....
•Universal AC input / Full range
•Protections: Short circuit / Overload / Over voltage
•Cooling by free air convection
•LED indicator for power on
•100% full load burn-in test
•All using 105℃ long life electrolytic capacitors
•Withstand 300VAC surge input for 5 second
•High operating temperature up to 70℃
•Withstand 5G vibration test
•High efficiency, long life and high reliability
•3 years warranty
■ Features :
CH1OUTPUT NUMBER
EMC IMMUNITY
EMC EMISSION