Data Sheet
SPECIFICATION
SAFETY &
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Conducted EN55032
EN55032Radiated
ESD EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Radiated Susceptibility
EFT/Burest
Surge
Conducted
1200Khrs MIL-HDBK-217F(25 )℃
EN50155 including EN61373 for shock & vibration, EN50121-3-2 for EMC
31.8*20.3*12.7mm (1.25*0.8*0.5 inch)
EMC EMISSION
VOLTAGE RANGE
SURGE VOLTAGE (100ms max.)
FILTER
PROTECTION
(Typ.)
INTERNAL POWER DISSIPATION
VOLTAGE ACCURACY
RATED POWER
SHORT CIRCUIT
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
WORKING TEMP.
CASE TEMPERATURE
WORKING HUMIDITY
COOLING
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SOLDERING TEMPERATURE
200Vdc
43~160Vdc
±1%
10W
50mVp-p
±0.2%
-40 ~ + (Refer to "Derating Curve")85℃
+100 max.℃
20% ~ 90% RH non-condensing
Free-air convection
-55 ~ +1 , 10 ~ 95%25 RH non-condensing℃
0.03% / (0 ~ 71 )℃℃
1.5mm from case of 1 ~ 3sec./260 max.℃
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: compliance to EN61373(Category 1- Class B)
I/P-O/P:3KVDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
1000pF
500mW 0.5A fast acting type
Fuse recommended. 0.5A Fast acting type
240KHz
Protection type : Continuous, automatic recovery
Single output models: 0.5%, Dual output models: 1%±±
REMOTE CONTROL
FUNCTION
Power ON: R.C. ~ -Vin >3.5~160Vdc or open circuit ; Power OFF: R.C. ~ -Vin <1.2Vdc or short
Parameter Standard
Parameter Standard
Test Level / Note
Test Level / Note
MTBF
RAILWAY STANDARD
DIMENSION (L*W*H)
EMC IMMUNITY
OTHERS
CASE MATERIAL
Non-Conductive black plastic
PACKING
16g
NOTE
1.All parameters are specified at normal input(110Vdc), rated load, 25 70% RH ambient. ℃
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 f & 47 f capacitor. μμ
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
5.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please
refer to EMI testing of component power supplies.(as available on http://www.meanwell.com)
File Name:RSDW10,RDDW10-SPEC 2018-03-15
OVERLOAD
120 ~ 180% rated output power
UNDER VOLTAGE LOCKOUT
Start-up voltage
Shutdown voltage 38Vdc
40Vdc
RIPPLE & NOISE
Note.2
LINE REGULATION Note.3
LOAD REGULATION Note.4
SWITCHING FREQUENCY
(Typ.)
ISOLATION CAPACITANCE (Typ.)
EMC
(5)
Note.
N/A
Class A with external components
Pi type
OVER VOLTAGE Protection type : Clamp by diode
Protection type : Recovers automatically after fault condition is removed
SAFETY STANDARDS
EAC TP TC 004 approved
RSDW10 & RDDW10 series
10W DIP Package Reliable Railway DC-DC Converter
Level 2, 3V/m
Level 2, 8KV air, 4KV contact±±
Level 2, 3V(e.m.f.)
Level 1, 0.5KV Line-Line
Level 1, 0.5KV