Datasheet

SPECIFICATION
MODEL RQ-65B RQ-65C RQ-65D
DC VOLTAGE
RATED CURRENT
OUTPUT
VOLTAGE ADJ. RANGE
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
5V 12V
CH2
-5V
CH3
5V
CH1
15V
CH2
-5V
CH3
12V
CH2
-15V
CH4
24V
CH3
5V
CH1
-12V
CH4
-12V
CH4
6A 2A 0.5A 5A 2A 0.5A 1.5A0.5A 1A4A 0.5A0.5A
0.5 ~ 8A 0.2 ~ 3A 0 ~ 1A 0.5 ~ 8A 0.2 ~ 3A 0 ~ 1A 0.2 ~ 3A0 ~ 1A
0.1 ~ 1.5A
0.5 ~ 8A 0 ~ 1A0 ~ 1A
62.5W 65W 68W
80mVp-p
120mVp-p
80mVp-p
80mVp-p
120mVp-p
80mVp-p
120mVp-p
80mVp-p
180mVp-p
80mVp-p 80mVp-p80mVp-p
CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V
±2.0% ±5.0% ±2.0% +10,-4% ±5.0% ±8.0%±5.0% ±2.0% ±5.0%±5.0%
±0.5%
±0.5%
±1.5%
+9,-5%
±0.5% ±0.5%
±0.5%
±1.5% ±0.5% ±1.5%
±6.0%
±0.5% ±2.0%±0.5%
±0.5%
±0.5%±0.5%
±3.0% ±1.0% ±4.0% ±1.0% ±3.0%±1.0% ±5.0% ±1.0%±1.0%
500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
60ms/230VAC 14ms/115VAC at full load
88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
47 ~ 63Hz
76% 78%76%
CH1: 5.75 ~ 6.75V
2A/115VAC 1.2A/230VAC
COLD START 40A/230VAC
<2mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
UL60950-1, TUV EN60950-1 approved
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
-25 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 )on +5V output
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
245.5Khrs min. MIL-HDBK-217F (25 )
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
File Name:RQ-65-SPEC 2015-07-09
Protection type : Hiccup mode, recovers automatically after fault condition is removed
129*98*38mm (L*W*H)
0.44Kg; 30pcs/13.2Kg/0.72CUFT
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
65W Quad Output Switching Power Supply
Universal AC input / Full range
Protections:Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105 long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
Features :
RQ-65 series
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
CURRENT RANGE
Note.6
RATED POWER Note.6
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
LINE REGULATION Note.4
LOAD REGULATION Note.5
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note 7)
CH1
OUTPUT NUMBER
EMC IMMUNITY
EMC EMISSION
Bauar
Sicherheit
egel gema
t gepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os