Data Sheet

SPECIFICATION
SAFETY &
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Conducted EN55032
Radiated
ESD EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Radiated Susceptibility
EFT/Burest
Surge
Conducted
F/G: 720Khrs ; H: 880Khrs MIL-HDBK-217F(25 )
EN50155 / IEC60571 including EN61373 for shock & vibration, EN50121-3-2 for EMC
50.8*25.4*10.2mm (2*1*0.4 inch)
EN55032
EMC EMISSION
VOLTAGE RANGE
SURGE VOLTAGE (100ms max.)
FILTER
PROTECTION
VOLTAGE ACCURACY
RATED POWER
SHORT CIRCUIT
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
WORKING TEMP.
CASE TEMPERATURE
WORKING HUMIDITY
COOLING
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SOLDERING TEMPERATURE
±1.5%
20W
60mVp-p
±0.2%
-40 ~ + (Refer to "Derating Curve")85
+105 max.
20% ~ 90% RH non-condensing
Free-air convection
-55 ~ +1 , 10 ~ 95%25 RH non-condensing
0.03% / (0 ~ 71 )℃℃
1.5mm from case of 1 ~ 3sec./260 max.
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
F/G: I/P-O/P 1.5KVDC, H: I/P-O/P 3KVDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
1000pF
H: 250KHz
F/G: Single output 350KHz, Dual output 400KHz
Protection type : Continuous, automatic recovery
Single output models: 0.5%, Dual output models: 1%±±
REMOTE CONTROL
FUNCTION
Power ON: >5.5~75Vdc or open circuit (F/G models) ; >3.5~75Vdc or open circuit (H models)
Power OFF: <1.2Vdc or short (F/G/H models)
Parameter Standard
Parameter Standard
Test Level / Note
Test Level / Note
MTBF
RAILWAY STANDARD
DIMENSION (L*W*H)
EMC IMMUNITY
OTHERS
CASE MATERIAL
Black coated copper with Non-Conductive Base
PACKING
35g
NOTE
1.All parameters are specified at normal input(F:24Vdc, G:48Vdc, H:110Vdc), rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 f & 47 f capacitor. μμ
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 0% to 100% rated load.
5.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please
refer to EMI testing of component power supplies.(as available on http://www.meanwell.com)
File Name:RSDW20,RDDW20-SPEC 2018-08-06
OVERLOAD
110 ~ 160% rated output power
UNDER VOLTAGE LOCKOUT
Start-up voltage
Shutdown voltage
RIPPLE & NOISE
Note.2
LINE REGULATION Note.3
LOAD REGULATION Note.4
SWITCHING FREQUENCY
(Typ.)
ISOLATION CAPACITANCE (Typ.)
EMC
(5)
Note.
N/A
Pi type
OVER VOLTAGE Protection type : Clamp by diode
Protection type : Recovers automatically after fault condition is removed
Class A/B with external components
SAFETY STANDARDS
EAC TP TC 004 approved
RSDW20 & RDDW20 series
F: 9~36Vdc , G: 18~75Vdc , H: 43~160Vdc
Fuse recommended. 24Vin models: 4A delay time Type, 48Vin models: 2A delay time Type, 110Vin models: 0.8A delay time Type
24Vin models : 50Vdc, 48Vin models : 100Vdc, 110Vin models : 200Vdc
EXTERNAL TRIM ADJ. RANGE
(Typ.)
±10% (Single output model only)
24Vin: 8Vdc, 48Vin: 16Vdc, 110Vin: 38Vdc
24Vin: 8.8Vdc, 48Vin: 17Vdc, 110Vin: 40Vdc
Level 2, 3V/m
Level 2, 8KV air, 4KV contact±±
Level 2, 3V(e.m.f.)
Level 1, 0.5KV Line-Line
Level 1, 0.5KV
20W 2"x1" Package Reliable Railway DC-DC Converter