Datasheet
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
PEAK CURRENT
RATED POWER
RIPPLE & NOISE (max.)
Note.2
OUTPUT
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
PROTECTION
AC CURRENT (Typ.)
800ms,50ms/230VAC 3000ms,50ms/115VAC at full load
16ms at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
83%
25A/115VAC 45A/230VAC
<2mA / 240VAC
105 ~ 150% rated output power
CH1:5.75 ~ 6.75V CH2:13.8 ~ 16.2V CH1:5.75 ~ 6.75V CH2:17.25 ~ 20.25V
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
-10 ~ +70 (Refer to "Derating Curve")℃
20 ~ 90% RH non-condensing
10ms/1ms
-20 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
213.5K hrs min. MIL-HDBK-217F (25 )℃
215*115*50mm (L*W*H)
1.2Kg; 12pcs/15.4Kg/0.92CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. Every output channel can provide up to the maximum current, but total load can't exceed the rated output power.
6. CH3(24V) peak current 20A, 1ms, repeatable in every 100ms. CH3(24V) output must be above 16V in the period of peak current.≦
File Name:QP-320-SPEC 2017-07-14
5V 5V12V 15V
CH2 CH2
24V 24V
CH3 CH3
-12V -15V
CH4 CH4
20A 20A10A 8A3A 3A2A 1.6A
2.5 ~ 20A
20A
2.5 ~ 20A
20A
0 ~ 10A
10A
0 ~ 10A
10A
0.2 ~ 5A
20A, 1ms(Note5)≦ 20A, 1ms(Note5)≦
0.2 ~ 5A0.2 ~ 2A
2A
0.2 ~ 1.6A
1.6A
316W
100mVp-p 100mVp-p150mVp-p 150mVp-p150mVp-p 150mVp-p150mVp-p 150mVp-p
CH1,2:+10,-5%
±3.0% ±3.0%±3.0% ±3.0%+10,-6% +10,-6%±10% ±10%
±1.0% ±1.0%±2.0% ±2.0%±2.0% ±2.0%±3.0% ±3.0%
±2.0% ±2.0%±3.0% ±3.0%±6.0% ±6.0%±8.0% ±8.0%
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
320W Quad Output with PFC Function
QP-320 series
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
CH1 & CH2 can be adjusted from -5% ~ +10%
With power good and fail signal output
Built-in remote sense function for CH1 & CH2
LED indicator for power on
100% full load burn-in test
20A peak load capability for 24V channel
3 years warranty
■
Features :
QP-320D QP-320F
CH1 CH1
OUTPUT NUMBER
WORKING TEMP.
WORKING HUMIDITY
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
SAFETY &
EMC
(Note 4)
4A/115VAC 2A/230VAC
POWER GOOD / POWER FAIL
FUNCTION
POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.98/115VAC at full load
EMC IMMUNITY
EMC EMISSION
Bauar
Sicherheit
egel gema
t gepruft
od