Data Sheet

SPECIFICATION
60W PWM Output KNX LED Driver
PWM-60-KN series
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
SETUP, RISE TIME
Note.2
HOLD UP TIME (Typ.)
VOLTAGE RANGE 3
Note.
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
Note.5
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
0 ~ 100%
200~4000Hz user changable via ETS
500ms, 80ms/ 115AC or 230VAC
16ms/115VAC or 230VAC
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC @ full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
<0.25mA / 277VAC
108 ~ 130% rated output power
Hiccup mode, recovers automatically after fault condition is removed
20 ~ 95% RH non-condensing
-35 ~ +80 , 10 ~ 95% RH
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
996K hrs min. Telcordia SR-332 (Bellcore) ; 271.03K hrs min. MIL-HDBK-217F (25 )
1. All parameters NOT specially mentioned are measured at 230VAC input, rated and 25 of ambient temperature.current
2. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
3. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
4. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected
by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
5. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75 or less.
6. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
7. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
8. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
DIMMING RANGE
PWM FREQUENCY (Typ.)
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
15 ~ 17V 28 ~ 34V
PWM-60-12 PWM-60-24
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMC IMMUNITY
Compliance to EN55015, EN61000-3-2 Class C (@load 60%) ; EN61000-3-3,GB17743 and GB17625.1,EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Line 2KV),EAC TP TC 020
EMC EMISSION Note.6
COLD START 50A(twidth=350 s measured at 50% Ipeak) at 230VAC; Per NEMA 410
μ
TOTAL HARMONIC DISTORTION
MAX. NO. of PSUs on 16A
CIRCUIT BREAKER
9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC
SHORT CIRCUIT
(Please refer to "STATIC CHARACTERISTIC" section)
THD< 20%(@load 60%/115VAC, 230VAC; @load 75%/277VAC)≧≧
(Please refer to “TOTAL HARMONIC DISTORTION” section)
<0.5W
STANDY POWER CONSUMPTION
Tcase=-35 ~ + (Please refer to OUTPUT LOAD vs TEMPERATURE” section)85
Tcase=+85
MAX. CASE TEMP.
ENEC EN61347-1, EN61347-2-13, EN62384 independent, GB19510.14,GB19510.1,EAC TP TC 004 approved
86% 89%
±℃ 0.03%/ (0 ~ 50 )
0.45Kg;30pcs/16.0Kg/1.0CUFT
150*53*35mm (L*W*H)
Shut down o/p voltage, re-power on to recover
12V 24V
5A 2.5A
60W 60W
0.8A / 115VAC 0.4A / 230VAC 0.32A / 277VAC
Shut down o/p voltage, re-power on to recover
File Name:PWM-60-KN-SPEC 2019-12-19
KNX STANDARDS
Certified protocol