Data Sheet
Mechanical Specification
Unit:mm
Mechanical Specification
Unit:mm
Block Diagram
CIRCUIT
CIRCUIT
DETECTION
ALARM
O.L.P.
EMI
FILTER
RECTIFIERS
&
FILTER
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
Bat. +
Battery Charger
&
Back Up Control
AC OK
Bat. Low
-V
Bat. -
I/P
FG
CONTROL
O.V.P.
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No.
1
2
3
Assignment
AC/N
No Pin
AC/L
Mating Housing
JST VHR JST SVH-21T-P1.1
or equivalent or equivalent
Terminal
DC Output Connector (CN2) : JST B6P-VH or equivalent
Pin No. Pin No.
1
5
4
2
36
Assignment Assignment
DC Output +
Battery +
DC Output COM
AC OK
Bat. Low
Battery -
Mating Housing
JST VHR
or equivalent
Terminal
JST SVH-21T-P1.1
or equivalent
1.HS1,HS2 can not be shorted.
2.HS1 must have safety isolation distance with system case.
3.M1 is safety ground. For better EMC performance,Please
secure an electrical connection between M1,M2 and
chassis grounding.
CN1
2
3
1
AC FUSE
FS1
T2.5A/250V
1
4
5
6
SVR1
CN2
101.6
95.25
3.175
HS2
2
3
HS1
4- 3.3ψ
50.8
44.45
3.175
29
3 max.
60W Single Output with Battery Charger(UPS Function)
PSC-60 series
L-Bracket:
No.998A -D
Mylar film
Cover:
No.998A -T
18
14.5
4.2
95
78
2-M3
12.7
2-M3 L=4
2-M3 L=4
55
103.4
24.2
30.85
62
2- 3.5ψ
37
: Grounding Required
M1
M2
File Name:PSC-60-SPEC 2019-06-10