Datasheet

SPECIFICATION
PS-05-5 PS-05-12 PS-05-15 PS-05-24 PS-05-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
LINEREGULATION
LOADREGULATION
HOLDUP TIME(Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
WORKINGHUMIDITY
WORKINGTEMP.
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
ACCURRENT (Typ.)
5V 12V 15V 24V 48V
1A 0.45A 0.35A 0.22A 0.11A
0~1.2A 0~0.5A 0~0.4A 0~0.25A 0~0.125A
5W 5.4W 5.25W 5.28W 5.28W
100mVp-p 120mVp-p 120mVp-p
2.0%
200mVp-p 200mVp-p
2.0% 2.0% 2.0% 1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
100msatfullload
85~264VAC120~370VDC
47~63Hz
70% 75%
13.8~16.2V 17.2~20.2V 27.6~32.4V 55.2~64.8V
75% 76% 76%
0.15A/115VAC0.07A/230VAC
COLDSTART 30A/230VAC
<0.5mA /240VAC
Above105% ratedoutputpower
5.75~6.75V
Protectiontype: Hiccupmode,recoveryautomaticallyafterfaultconditionisremoved
Protectiontype:Hiccupmode,recoveryautomaticallyafterfaultconditionisremoved
-10~+60 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-20~+85 ,10~95%RH
0.05%/ (0~50
10~500Hz,2G10min./1cycle,Periodfor60min.eachalongX, Y,Zaxes
75*40*20mm(L*W*H)
0.05Kg;120pcs/6.25Kg/1CUFT
FileName:PS-05-SPEC2009-07-03
OVERTEMPERATURE
HARMONICCURRENT
EMSIMMUNITY
EN60950-1CB Approvedby TUV
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
Complianceto EN61000-4-2,3,4,5,6,8,11Lightindustrylevel,criteria A
5WSingleOutputSwitchingPowerSupply
PS-05 series
Features :
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVAC
I/P-O/P:100MOhms/500VDC
EMICONDUCTION&RADIATION
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
Tj140 typically(U1)DetectonmaincontrolIC
Universal AC input / Full range
Low leakage current <0.5mA
Protections: Short circuit/Over load /Over voltage/Over temperature
Cooling by free air convection
100% full load burn-in test
Fix switching frequency at 67KHz
Low cost
High reliability
2 years warranty
SETUP,RISE TIME
1000ms,20ms
Protectiontype:shutoffo/pvoltage,clampingbyzenerdiode
MTBF
1271.1Khrsmin.MIL-HDBK-217F(25 )

Summary of content (2 pages)