Datasheet
SPECIFICATION
PS-05-5 PS-05-12 PS-05-15 PS-05-24 PS-05-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
HOLD UP TIME(Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
5V 12V 15V 24V 48V
1A 0.45A 0.35A 0.22A 0.11A
0 ~ 1.2A 0 ~ 0.5A 0 ~ 0.4A 0 ~ 0.25A 0 ~ 0.125A
5W 5.4W 5.25W 5.28W 5.28W
100mVp-p 120mVp-p 120mVp-p 200mVp-p 200mVp-p
±2.0% ±2.0% ±2.0% ±2.0% ±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
100ms at full load
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
70% 75%
13.8 ~ 16.2V 17.2 ~ 20.2V 27.6 ~ 32.4V 55.2 ~ 64.8V
75% 76% 76%
0.15A/115VAC 0.07A/230VAC
COLD START 30A/230VAC
<0.5mA / 240VAC
Above 105% rated output power
5.75 ~ 6.75V
Protection type : Hiccup mode, recovery automatically after fault condition is removed
Hiccup mode, recovery automatically after fault condition is removed
-10 ~ +60 (Refer to "Derating Curve")℃
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH℃
±℃ ℃0.05%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
75*40*20mm (L*W*H)
0.05Kg; 120pcs/6.25Kg/1CUFT
File Name:PS-05-SPEC 2017-07-07
OVER TEMPERATURE
HARMONIC CURRENT
EMS IMMUNITY
IEC60950-1 CB approved by TUV
Compliance to EN55032 (CISPR32) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
5W Single Output Switching Power Supply
PS-05 series
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
EMI CONDUCTION & RADIATION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
Universal AC input / Full range
Low leakage current <0.5mA
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
100% full load burn-in test
Fix switching frequency at 67KHz
Low cost
High reliability
2 years warranty
SETUP, RISE TIME
1000ms, 20ms
■ Features :