Datasheet
Between RC+(pin10) and RC-(pin9)
SW Ope n
SW Short
Charger
ON
OFF
The charg er can be turned ON/OFF by using the
The charg er may be hooked up tw o battery banks (A and /or B). Connect the bat tery bank(s) as below. If you are connecting 2 battery banks in the
sa me time, keep in mind that they must s hare a common ground .
"Remote C ontrol" function .
SW
9
10
CN100
RY13
RY14
RY15
GND
RC-
RY13
RY14
RY15
RTH
RC+
1
2
File Name :PB-10 00-SP EC 201 3-08-05
PB-1000
series
Function Manual
1.Remote Control
2.Two Battery Banks
Stage 8 /3/2
Stage 8/3/2 Stage 8/3/2
++
+ +
Battery ABattery B
Battery A Battery B
--
- -
Stage 8/3 /2
++
Battery ABattery B
--
1000W Intelligent Single Output Battery Charger
Function Description of CN100
Pin No. Function
Description
1,2
3,4
5,6
7,8
9,10
RY13
Relay contact rating(max.) : 30V/1A resistive. ; "Short" when the battery A is full, "Open" when the battery A is still charging.
Relay contact rating(max.) : 30V/1A resistive. ; "Short" when the battery B is full, "Open" when the battery B is still charging.
Relay contact rating(max.) : 30V/1A resistive. ; "Short" when the unit is working properly, "Open" when the uni t is failure or
Temperature sensor comes along with the charger can be connected to the unit to allow temperature compensation of the
Turn the output on and off by electrical or dry contact between pin 10 (RC+) and pin 9(RC-), "Open" : Normal work ,
"Short" : Stop charging
the protection function is activating.
charging voltage.
If the temperature sensor is not used, the charger still works normally.
RY14
RY15
GND / RTH