Datasheet

SPECIFICATION
LPP-100-3.3 LPP-100-5 LPP-100-7.5 LPP-100-12 LPP-100-13.5 LPP-100-15 LPP-100-24 LPP-100-27 LPP-100-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.5
FREQUENCY RANGE
POWERFACTOR (Typ.)
LEAKAGECURRENT
WORKINGHUMIDITY
WORKINGTEMP.
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V
20A 20A 13.5A 8.5A 7.5A 6.7A 4.2A
0~4.2A
100.8W
3.8A 2.1A
0~20A 0~20A 0~13.3A 0~8.5A 0~7.5A 0~6.7A 0~3.8A 0~2.1A
66W 100W 101.25W 102W 101.25W 100.5W 102.6W 100.8W
100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p
3.14~3.63V 4.75~5.5V 7.13~8.25V 11.4~13.2V 12.8~14.9V 14.3~16.5V 22.8~26.4V 25.7~29.7V 45.6~52.8V
2.0% 2.0% 2.0% 2.0% 1.0% 1.0% 1.0%
0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
1.0%
2.0%
1.0%
2.0%
1.0% 0.5%0.5%0.5%0.5% 0.5% 0.5%
600ms,30ms/230VAC1200ms,30ms/115VACatfullload
28ms/230VAC28ms/115VACatfullload
85~264VAC120~370VDC
47~63Hz
PF>0.95/230VACPF>0.98/115VAC atfullload
69%
1.7A/115VAC0.75A/230VAC
75% 76% 79% 79% 80% 83% 83% 83%
COLDSTART 30A/230VAC
<2mA /240VAC
105~150% ratedoutputpower
3.8~4.45V 5.75~6.75V 8.6~10.1V 13.8~16.2V 15.5~18.2V
17.25~20.25V
27.6~32.4V 31~36.45V 55.2~64.8V
Protectiontype:Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
20~90%RHnon-condensing
-10~+60
(Referto"DeratingCurve")
-20~+85 ,10~95%RH
0.05%/ (0~50
10~500Hz,2G10min./1cycle,periodfor60min. eachalongX, Y,Zaxes
224.3Khrsmin.MIL-HDBK-217F(25 )
222*62*33.6mm(L*W*H)
0.51Kg;24pcs/13.9Kg/1.39CUFT
FileName:LPP-100-SPEC2012-02-03
SAFETY STANDARDS
UL60950-1, TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,EN55024,lightindustrylevel,criteria A
100WSingleOutputwithPFCFunction
LPP-100 s er ie s
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
Features :
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
EFFICIENCY(Typ.)
INPUT
INRUSHCURRENT (Typ.)
ACCURRENT (Typ.)
EMCIMMUNITY
EMCEMISSION

Summary of content (2 pages)