Instruction Manual
Table Of Contents
File Name:LCM-40TW-SPEC 2022-03-06
DIMMING OPERATION
‧DALI protocol comprises 16 groups and 64 addresses.
‧First step is fixed at 0.2%.
※DALI interface(primary side; for DA2-Type)
‧Apply DALI signal between DA+ and DA-
LCM-40TW
DA+/PUSH
AC/N
AC/L
DA+
AC/N
AC/L
40W Constant Power Mode With Tunable White LED Driver
LCM-40TW series
DA-/N
DA-
LCM-40TW
Push Button
AC/N
AC/L
DA+/PUSH
AC/N
AC/L
DA-/N
※Output wiring diagram
※PUSH dimming (primary side)
Function
Action
Action duration
Short Push
0.1~1s
Double Click
Click twice in 1.5s
Long Push
1.5~10s
Status
Output
Push button function
DT6
Single Address
CH1
Short Push : ON/OFF
Double Click : go to maximum.
Long Push: Dim up/down.
- stop at max./min. level
- with next push, direction change
(up/down)
- dim up possible even if when unit is in
standby mode (dim off mode)
DT6
Dual Address
CH1,CH2
Short Push: ON/OFF
Double Click : go to maximum.
Long Push : Dim up+CCT cooler/Dim
down+CCT warmer
- dim up stop at maximum; dim down stop
at min dim (not dim off)
- with next push, up or down direction will
change
- dim up possible even if when unit is in
standby mode (dim off mode)
DT8
CH1(C) ,
CH2(W)
Short Push : ON/OFF
Double Click : Switch between Dim
control or CCT control mode
Long Push : Dim up/down or CCT control
- stop at max./min. level
- with next push, direction change
(up/down, warm/cold)
- dim up possible even if when unit is in
standby mode (dim off mode)
•The factory default dimming level is at 100%.
•If the push action lasts less than 0.05 sec., it will not lead to a change for the status of the driver.
•Up to 10 drivers can perform the PUSH dimming at the same time when utilizing one common push button.
•The maximum length of the cable from the push button to the last driver is 20 meters.
•The additive push button can be connected only between the PUSH terminal, as displayed in the diagram,
and AC/L (in brown or black); it will lead to short circuit if it is connected to AC/N.