SPECIFICATION
MODEL
LCM-40TW
OUTPUT
OUTPUT CHANNEL
CH1
CH2
DC VOLTAGE RANGE
20~50V
20~50V
RATED POWER
40W Max. total
NO LOAD VOLTAGE
53V
53V
CURRENT ADJ. RANGE
(BY DIP SWITCH)
500~1050mA
500~1050mA
CURRENT RIPPLE Note5
<2%
DIMMING RANGE
0~100%
START UP TIME Note9
500ms/230VAC
INPUT
VOLTAGE RANGE
180~277VAC 260~390VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF≥0.98/230VAC,PF≥0.95/277VAC@full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
TOTAL HARMONIC
DISTORTION
THD< 10%(@load 50%/230VAC; @load 75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
EFFICIENCY(Typ.) Note4
87%
AC CURRENT
0.23A/230VAC
INRUSH CURRENT
COLD START 20A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
LEAKAGE CURRENT
<0.75mA / 277VAC
STANDBY POWER
CONSUMPTION Note6
standby power consumption<0.5W (Dimming off)
PROTECTION
OVERLOAD
105~135% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed.
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
OVER TEMPERATURE
Stage 1: Derating to 70% loading; stage2: Shut down.Recovers automatically after fault condition is removed
ENVIRONMENT
WORKING TEMP.
Tcase=-30~85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.
Tcase=85℃
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
OPERATING ALTITUDE
2000 meters
SAFETY&EMC
SAFETY STANDARDS
ENEC EN61347-1, EN61347-2-13, EN62384 independent, GB19510.14,GB19510.1, EAC TP TC 004 approved
DALI STANDARDS
Comply with IEC62386-101, 102, 207(DT6),209(DT8),251
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to EN55015, EN61000-3-2 Class C(@load 50%) ; EN61000-3-3; GB17625.1,GB17743, EAC TP TC 020
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level(surge immunity Line-Line 2KV), EAC TP TC 020
OTHERS
MTBF
2111.7K hrs min. Telcordia SR-332 (Bellcore) 177.4Khrs min. MIL-HDBK-217F (25 )℃
DIMENSION
123.5*81.5*23mm (L*W*H)
PACKING
0.24Kg ; 54pcs/15Kg/1.12CUFT
NOTE
℃
~
℃ ℃
※ : , https://www.meanwell.com/serviceDisclaimer.aspx
File Name:LCM-40TW-SPEC 2022-03-06
40W Constant Power Mode With Tunable White LED Driver