Data Sheet

SPECIFICATION
480W Constant Power Mode LED Driver
HVGC-480 series
File Name:HVGC-480-SPEC 2018-09-30
MODEL
RATED CURRENT
RATED POWER
FULL POWER CURRENT RANGE
OUTPUT
CURRENT ADJ. RANGE(Typ.)
VOLTAGE RANGE
Note.3
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
VIBRATION
MTBF
DIMENSIONOTHERS
OVER VOLTAGE
OVER TEMPERATURE
700~1750mA
47 ~ 63Hz
1.52A / 347VAC 1.11A / 480VAC
<0.75mA / 480VAC
Compliance to ,EN55015, EN61000-3-2 Class C ( ); EN61000-3-3, FCC Part 15 class B@ load 50% EAC TP TC 020≧
Compliance to ,EN61000-4-2,3,4,5,6,8,11, EN61547,
light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV)
EAC TP TC 020
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH non-condensing
℃
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750 (type”HL”),
CSA C22.2 No. 250.13-14,
,
ENEC EN61347-1, EN61347-2-13 independent, EN62384, IP65 or IP67 EAC TP TC 004 approved
286.1K hrs min. Telcordia SR-332(Bellcore) ; 72.9K hrs min. MIL-HDBK-217F (25 )℃
262*125*43.8mm (L*W*H)
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
94.5% 94.5% 94.5%
1400mA
480W
1400~1750mA
480W 480W
2100mA 2800mA
EMC IMMUNITY
EMC EMISSION
COLD START 40A(t =1100 s measured at 50% I ) at 480VAC;
width peak Per NEMA 410
TOTAL HARMONIC DISTORTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
℃
CONSTANT CURRENT REGION
Note.2
PACKING
2.72Kg;4pcs/11.45Kg/0.55CUFT
NOTE
μ
MAX. NO. of PSUs on 16A
CIRCUIT BREAKER
2 unit(circuit breaker of type B) / 4 units(circuit breaker of type C) at 480VAC
Constant current limiting, recovers automatically after fault condition is removed
Shut down output voltage, re-power on to recovery
(Please refer to "STATIC CHARACTERISTIC" section)
180 ~ 528VAC 254VDC ~ 747VDC
137 ~ 343V
92 ~ 228.5V 68 ~ 171.5V
OPEN CIRCUIT VOLTAGE (max.)
350V
351 ~ 381V
241 ~ 257V 181 ~ 193V
Shut down output voltage, re-power on to recovery
240V 180V
1050~2625mA 1400~3500mA
2100~2625mA 2800~3500mA
TEMP. COEFFICIENT
±℃ ℃0.03%/ (0 ~ 60 )
HVGC-480-L- HVGC-480-M- HVGC-480-H-
1. All parameters NOT specially mentioned are measured at 347VAC input, rated current and 25 of ambient temperature.℃
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
5. The is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by thedriver
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 80 or less.℃
7. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED can only be used behind a switch without permanently connected to
driver
the mains.
9. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
10. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
WORKING TEMP.
Tcase=-40 ~ +90 (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)℃
MAX. CASE TEMP.
Tcase=+90℃
PF 0.9 / 230VAC, PF 0.9 / 277VAC full load≧≧≧≧≧8 8 , PF 0.97 / 347VAC, PF 0.96 / 400VAC, PF 0.95 / 480VAC at
(Please refer to " " )Power Factor Characteristic section
THD< 20% (@ load 50% at 230VAC/277VAC/347VAC/400VAC/480VAC input≧
(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
CURRENT RIPPLE 5.0% max. @rated current
CURRENT TOLERANCE ±
5%
SET UP TIME
Note.4 500ms/230VAC, 347VAC, 480VAC