Data Sheet

WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
CONSTANT CURRENT REGION
Note.4
HLN-80H-12
A
B : IP64 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
Note.6
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.8
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
Note.7
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
Note.4
OVER VOLTAGE
OVER TEMPERATURE
Can be adjusted by internal potentiometer A type only
16ms at full load 230VAC /115VAC
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
COLD START 70A(twidth=485 s measured at 50% Ipeak) at 230VACμ
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN55015, EN61000-3-2 Class C ( 60% load, 12V model 65% load) ; EN61000-3-3≧≧
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 40 )
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
356.4Khrs min. MIL-HDBK-217F (25 )
181*61.5*35mm (L*W*H)
0.5Kg; 24pcs/13Kg/0.75CUFT
Protection type : Shut down o/p voltage, re-power on to recover
80W Single Output Switching Power Supply
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
Fully isolated plastic case with IP64 level
Class 2 power unit
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp locations or outdoor application
3 years warranty
Features :
HLN-80H series
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
SELV
IP64
A : IP64 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
14 ~ 17V 18 ~ 24V
23 ~ 30V
28 ~ 35V
35 ~ 43V
41 ~ 49V 54 ~ 63V
48 ~ 58V 59 ~ 68V
88%
89%
90%
90.5%
91%
91%
91%91% 91%
±2.5% ±2.0% ±1.0% ±1.0% ±1.0%
±1.0%
±1.0%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±0.5%
±0.5%
±2.0%
±1.5% ±1.0% ±0.5% ±0.5%
±0.5%
±0.5%
±1.0%
±0.5%
±0.5%
±1.0%
±0.5%
±0.5%
12V
HLN-80H-12 HLN-80H-30HLN-80H-15 HLN-80H-36HLN-80H-20 HLN-80H-42HLN-80H-24 HLN-80H-48 HLN-80H-54
15V 20V 24V 30V
36V
48V
5A 5A 4A 3.4A
2.7A
2.3A
1.7A
60W 75W 80W 81.6W 81W
82.8W
81.6W
150mVp-p 150mVp-p
13.5 ~ 17V
150mVp-p
17 ~ 22V
150mVp-p
22 ~ 27V
200mVp-p
27 ~ 33V
200mVp-p
33 ~ 40V
200mVp-p
43 ~ 53V10.8 ~ 13.5V
54V
1.5A
81W
200mVp-p
49 ~ 58V
42V
1.95A
81.9W
200mVp-p
38 ~ 46V
FMM
110
PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
0.85A / 115VAC 0.425A / 230VAC 0.4A / 277VAC
UL8750, CSA C22.2 No. 250.0-08(except for 48V, 54V), EN61347-1, EN61347-2-13 independent ; IP64, J61347-1,
J61347-2-13 approved ; Design refer to UL60950-1, TUV EN60950-1
3 ~ 5A 3 ~ 5A 2.4 ~ 4A 2.04 ~ 3.4A 1.62 ~ 2.7A
1.38 ~ 2.3A
1.02 ~ 1.7A 0.9 ~ 1.5A
1.17 ~ 1.95A
7.2 ~12V 9 ~ 15V 12 ~ 20V 14.4 ~ 24V 18 ~ 30V
21.6 ~ 36V
28.8 ~ 48V 32.4 ~ 54V
25.2 ~ 42V
-40 ~ +50 (Refer to "Derating Curve")
EMC IMMUNITY
EMC EMISSION
( except for 48V,54V )( for 48V,54V only)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
File Name:HLN-80H-SPEC 2014-08-14
1200ms,80ms/115VAC 500ms,80ms/230VAC at full load ; B type 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. A type only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by
the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.

Summary of content (5 pages)