Datasheet
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
CONSTANT CURRENT REGION
Note.4
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
Note.6
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.8
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY
(Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
Note.7
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
OVER CURRENT
Note.4
OVER VOLTAGE
OVER TEMPERATURE
Can be adjusted by internal potentiometer A type only
500ms, 80ms at full load 230VAC /115VAC
15ms at full load 230VAC /115VAC
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN55015, EN55022(CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3≧
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
-40 ~ +70 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
± ℃ ℃0.03%/ (0 ~ 60 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, EN61347-1, EN61347-2-13 independentCSA C22.2 No. 250.13-12, , approvedIP65 or IP67
76.9K hrs min. MIL-HDBK-217F (25 )℃
280*144*48.5mm (L*W*H)
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
13 ~ 16V 16.5 ~ 20.5V 22 ~ 26V 26 ~ 30V
32.5 ~ 36.5V
39.5 ~ 43.5V 52.5 ~ 56.5V
46 ~ 50V 59 ~ 63V
92%
92.5%
93.5%
93.5%
94.5%
94.5%
95%
95%
95%
95%
95.5%
95.5%
96%
96%
96%
96%
96%
96%
±3.0%
20 ~ 40A
±2.0%
18 ~ 36A
±1.5%
14 ~ 28A
±1.0%
12.5 ~ 25A
±1.0%
10 ~ 20A
±1.0%
8.3 ~ 16.7A
±1.0%
6.2 ~ 12.5A
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±0.5%
±0.5%
±2.0% ±1.5% ±1.0% ±0.5% ±0.5%
±0.5%
±0.5%
±1.0%
5.6 ~ 11.2A
±0.5%
±0.5%
±1.0%
7.1 ~ 14.3A
±0.5%
±0.5%
HLG-600H-12
HLG-600H-15 HLG-600H-20
HLG-600H-24
HLG-600H-30
HLG-600H-36
HLG-600H-48
12V
6 ~12V
15V
7.5 ~ 15V
20V
10 ~ 20V
24V
12 ~ 24V
30V
15 ~ 30V
36V
18 ~ 36V
48V
24 ~ 48V
40A 36A 28A 25A 20A
16.7A
12.5A
480W 540W 560W 600W 600W
601.2W
600W
150mVp-p 150mVp-p
12.7 ~ 15.8V
150mVp-p
17 ~ 21V
150mVp-p
20.4 ~ 25.2V
200mVp-p
25.5 ~ 31.5V
250mVp-p
30.6 ~ 37.8V
250mVp-p
40.8 ~ 50.4V10.2 ~ 12.6V
HLG-600H-54
54V
27 ~ 54V
11.2A
604.8W
350mVp-p
45.9 ~ 56.7V
HLG-600H-42
42V
21 ~ 42V
14.3A
600.6W
250mVp-p
35.7 ~ 44.1V
EMC IMMUNITY
EMC EMISSION
COLD START 70A(t =1000 s measured at 50% I ) at 230VAC
width peak
μ
TOTAL HARMONIC DISTORTION
THD< 20% when output loading 50% at 115VAC/230VAC input and output loading 75% at 277VAC input≧ ≧
230VAC
277VAC
FUNCTION
REMOTE ON/OFF CONTROL
Power on : "Hi" >2 ~ 5V or (Open circuit) Power off : "Low" <0 ~ 0.5V or (Short circuit)
600W Single Output Switching Power Supply
HL G- 60 0H
s eri es
File Name:HLG-600H-SP EC 2014-05-1 2
5V STANDBY
5V : 5V@0.5A ; tolerance 5%, ripple : 100mVp-p(max.)
SB
±
PACKING
3.9Kg; 4pcs/16.6Kg/0.9CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50%~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. A type only.
7. Safety and EMC design refer to EN60598-1, subject CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement