Datasheet
Address
CN71
13
1
14
2
Note1: Non-isolated signal, referenced to [GND(signal)].
Note2: Isolated signal, referenced to GND-AUX.
Description
Auxiliary voltage output, 10.8~13.2V, referenced to GND-AUX (pin9 & 10).
Low (-0.5 ~ 0.5V) : When Vout 77% 6% at power mode. Vout 66% 6% at charger mode.≦± ≦±
The maximum load current is 0.5A. This output is not controlled by “Remote ON-OFF”.
High (4.4 ~ 5.5V) : When Vout 80% 6% at power mode. Vout 67% 6% at charger mode.≧± ≧±
The maximum sourcing current is 10mA and only for output.(Note.2)
The unit can turn the output ON/OFF by dry contact between Remote ON/OFF and +12-AUX.(Note.2)
Short (10.8 ~ 13.2V) : Power ON ; Open(0 ~ 0.5V) : Power OFF ; The maximum input voltage is 13.2V
※Control Pin No. Assignment(CN71) : JST S14B-PHDKS-B or equivalent
Mating Housing
Terminal
JST PHDR-14VS or equivalent
JST SPHD-001T-P0.5 or equivalent
1
Connection for output voltage programming.(Note1)
2
Connection for constant current level programming.(Note.1)
Negative output voltage signal.
For PMBus model: Serial Data used in the PMBus interface. (Note.2)
For CANBus model: Data line used in CANBus interface. (Note.2)
For PMBus model: Serial Clock used in the PMBus interface. (Note.2)
For CANBus model: Data line used in CANBus interface. (Note.2)
Auxiliary voltage output GND.
The signal return is isolated from the output terminals (+V & -V).
21
14 13
Pin No.
7,8
11
12
9,10
5
3,4
6
Function
+12V-AUX
DC-OK
Remote
ON-OFF
PC
GND (Signal)
SDA
CANH
SCL
CANL
GND-AUX
PV
13 RTH+
14 RTH-
Temperature sensor(NTC, 5KOhm) comes along with the charger can be connected to the unit to allow temperature
compensation of the charging voltage.
MECHANICAL SPECIFICATION
Case No.228F Unit:mm
1000W Power Supply for Harsh EnvironmentSwitching
HEP-1000 series
AC Input Terminal Pin No. Assignment DC Output Terminal Pin No. Assignment
Pin No. Pin No.
1 1,2
3
2 3,4
Assignment Assignment
AC/L +V
-V
AC/N
FG
※ Output voltage current level can be adjusted through internal potentiometer.(Vo Adj.)
(Can access by removing the rubber stopper on the case.)
PMBus interface address selection.(Address)※
INSTALLATION MANUAL
Please refer to : http://www.meanwell.com/manual.html
Vo Adj.
4 4.5-ψ
46-ψ
5.7
8.9
13.4
283.2
310
7
15
97
15
7
5.7
144
11
9.25
LED
19.3 max.
48.5
19.3 max.
1
2
3
1
2
3
4
I/P O/P
File Name:HEP-1000-SPEC 2019-09-25
1
2
3
4