Data Sheet

300W Constant Power Mode LED Driver
HBGC-300 series
File Name:HBGC-300-SPEC 2018-09-30
SPECIFICATION
MODEL
DEFAULT CURRENT
RATED POWER
FULL POWER CURRENT RANGE
OUTPUT
CURRENT ADJ. RANGE
VOLTAGE RANGE
Note.2
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
VIBRATION
MTBF
DIMENSIONOTHERS
OVER VOLTAGE
OVER TEMPERATURE
650~2170mA
47 ~ 63Hz
3A / 115VAC 1.6A / 230VAC 1.3A / 277VAC
<0.75mA / 277VAC
Compliance to EN55015, EN61000-3-2 Class C ( ); EN61000-3-3@ load 50%≧
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV)
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH non-condensing
℃
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
561.2K hrs min. Telcordia SR-332(Bellcore) ; 154.9K hrs min. MIL-HDBK-217F (25 )
℃
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
94.5% 93.5% 92.5%
1400mA
301.6W
1300~2170mA
301.6W 301.6W
2800mA 5600mA
EMC IMMUNITY
EMC EMISSION
COLD START 45A(twidth=1300 s measured at 50% Ipeak) at 230VAC; Per NEMA 410
TOTAL HARMONIC DISTORTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
℃
CONSTANT CURRENT REGION
PACKING
2.2Kg;8pcs/19.8Kg/2.09CUFT
NOTE
μ
MAX. NO. of PSUs on 16A
CIRCUIT BREAKER
2 unit(circuit breaker of type B) / 4 units(circuit breaker of type C) at 230VAC
Constant current limiting, recovers automatically after fault condition is removed
Tcase>80 5 ,derate power automatically by 6%/ max.℃± ℃ ℃
(Please refer to "STATIC CHARACTERISTIC" section)
90 ~ 305VAC 127VDC ~ 431VDC
116 ~232V
58 ~ 116V 29 ~ 58V
OPEN CIRCUIT VOLTAGE (max.)
240V
241 ~ 275V
121 ~ 145V 61 ~ 78V
Shut down output voltage, re-power on to recovery
120V 62V
1300~4330mA 2600~8670mA
2600~4330mA 5200~8670mA
TEMP. COEFFICIENT
±℃ ℃0.03%/ (0 ~ 60 )
HBGC-300-L- HBGC-300-M- HBGC-300-H-
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature.℃
2. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
3. The is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by thedriver
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
4. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 70 or less.℃
5. To fulfill requirements of the latest ErP regulation for lighting fixture, this LED drive can only be used behind a switch without permanently connected
to the mains.
6. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
7. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
8. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
WORKING TEMP.
Tcase=-40 ~ +80 (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)℃
MAX. CASE TEMP.
Tcase=+80℃
PF 0.97 / 115VAC, PF 0.95 / 230VAC full load≧≧≧, PF 0.92 / 277VAC at
(Please refer to " " )Power Factor Characteristic section
THD< 10% (@ load 50% at 115VAC/230VAC ,@load 75% at 277VAC)≧≧
Please refer to “TOTAL HARMONIC DISTORTION (THD)” section
CURRENT RIPPLE 5.0% max. @rated current
CURRENT TOLERANCE ±
5%
SET UP TIME
500ms/230VAC, 500ms/115VAC
Blank/A-Type please refer to Note. 5
NO LOAD / STANDBY
POWER CONSUMPTION
Standby power consumption <0.5W for AB / DA-Type
UL8750 ENEC EN61347-1, EN61347-2-13 independent, EN62384(type”HL”), CSA C22.2 No. 250.13-12; ;
GB19510.1 GB19510.14, ; IP67 approved
LIFETIME Note.4
50000 hrs min.
φ191.5mm *69mm