Datasheet

SPECIFICATION
MODEL
OUTPUT
VOLTAGE RANGE Note.5
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
EMC IMMUNITY
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER TEMPERATURE Note.12
OVER VOLTAGE
47 ~ 63Hz
<0.75mA / 277VAC
20 ~ 95% RH non-condensing
-40 ~ +80, 10 ~ 95% RH
±0.03%/ (0 ~ 50)
ENVIRONMENT
EMC EMISSION
SAFETY &
EMC
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
TOTAL HARMONIC DISTORTION
DC VOLTAGE
RATED CURRENT
RATED POWER Note.5
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
RIPPLE & NOISE (max.) Note.3
VOLTAGE TOLERANCE Note.4
CONSTANT CURRENT REGION Note.2
OVER CURRENT
SAFETY STANDARDS
COLD START 75A(twidth=680 s measured at 50% Ipeak) at 230VACμ ; Per NEMA 410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC
(Please refer to "STATIC CHARACTERISTIC" section)
90 ~ 305VAC 127 ~ 431VDC
1.AllparametersNOTspeciallymentionedaremeasuredat230VACinput,ratedcurrentand25ofambienttemperature.
2.Pleasereferto"DRIVINGMETHODSOFLEDMODULE".
3.Ripple&noisearemeasuredat20MHzofbandwidthbyusinga12"twistedpair-wireterminatedwitha0.1uf&47ufparallelcapacitor.
4.Tolerance:includessetuptolerance,lineregulationandloadregulation.
5.De-ratingmaybeneededunderlowinputvoltages.Pleasereferto“STATICCHARACTERISTIC”sectionsfordetails.
6.Lengthofsetuptimeismeasuredatfirstcoldstart.TurningON/OFFthedrivermayleadtoincreaseofthesetuptime.
7.Thedriverisconsideredasacomponentthatwillbeoperatedincombinationwithfinalequipment.SinceEMCperformancewillbeaffectedbythe
completeinstallation,thefinalequipmentmanufacturersmustre-qualifyEMCDirectiveonthecompleteinstallationagain.
8.TofulfillrequirementsofthelatestErPregulationforlightingfixtures,thisLEDdrivercanonlybeusedbehindaswitchwithoutpermanently
connectedtothemains.
9.Thisseriesmeetsthetypicallifeexpectancyof>50,000hoursofoperationwhenTaisabout45orless.
10.PleaserefertothewarrantystatementonMEANWELL'swebsiteathttp://www.meanwell.com
11.Theambienttemperaturederatingof3.5/1000mwithfanlessmodelsandof5/1000mwithfanmodelsforoperatingaltitudehigherthan2000m(6500ft).
12.Allfunctionaltestingmustbefilledwithpotting,includingOTPfunction.
95 ~ 108%
PF0.98/115VAC, PF0.94/230VAC, PF0.9/277VAC@full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
THD< 20%(@load60%/115VC,230VAC; @load75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
Ta=-40 ~ +45 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
2500ms, 120ms / 115VAC 500ms, 120ms / 230VAC
15ms/115VAC,230VAC
±2.0%
±0.5%
±0.5%
36V
21.6 ~ 36V
6.7A
241.2W
250mVp-p
HBG-240P-36
60V
36 ~ 60V
4.0A
240W
350mVp-p
HBG-240P-60
48V
28.8 ~ 48V
5A
240W
250mVp-p
HBG-240P-48
4.0 ~ 6.7A
3 ~ 5A
2.4 ~ 4.0A
92.5%
93.5%
93%
43 ~ 52V
62 ~ 85V
52 ~ 63V
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
175Khrs min. MIL-HDBK-217F (25)
Refer to mechanical specification
UL8750,CSA C22.2 No.250.13-12; ENEC EN61347-1,EN61347-2-13,EN62384, GB19510.1,GB19510.14 approved,EAC TP TC 004
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
Compliance to EN55015, EN61000-3-2 Class C (@load75%) ; EN61000-3-3, GB17743, GB17625.1, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547,light industry level(surge immunity:Line-Earth:4KV,Line-Line:2KV), EAC TP TC 020
HBG-240P series
240W Constant Voltage + Constant Current LED Driver
Adjustable for A-Type only (via built-in potentiometer)
2.8A / 115VAC 1.4A / 230VAC 1.2A / 277VAC
Constant current limiting, recovers automatically after fault condition is removed
Shut down and latch off o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
0.62Kg; 20pcs/13.4Kg/1.11CUFT
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed.
File Name:HBG-240P-SPEC 2018-12-06