Datasheet

SPECIFICATION
36WAC-DC High Reliability IndustrialAdaptor
GST36E series
File Name:GST36E-SPEC 2015-06-24
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.)
Note.3
OUTPUT
SETUP, RISE, HOLD UP TIME
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 8)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V
GST36E05
9V
GST36E09
12V
GST36E12
24V
GST36E24
48V
GST36E48
90mVp-p 90mVp-p 100mVp-p 180mVp-p 240mVp-p
VOLTAGE TOLERANCE
Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0% ±5.0% ±3.0% ±2.0% ±2.0%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0% ±3.0% ±2.0% ±2.0%
47 ~ 63Hz
0.25mA / 240VAC
TUV EN60950-1 approved
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
692.3Khrs min. MIL-HDBK-217F(25 )
20% ~ 90% RH non-condensing
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
79*54*33mm (L*W*H)
CONNECTOR
PLUG
CABLE
Compliance to EN55022 class B, EN61000-3-2,3
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
OVERLOAD
OVER VOLTAGE
Protection type : Clamp by zener diode
3A
0 ~ 3A
36W
EMC IMMUNITY
EMC EMISSION
GST36E05-P1J GST36E09-P1J GST36E12-P1J GST36E24-P1J GST36E48-P1J
Protection type : Hiccup mode, recovers automatically after fault condition is removed
1.5A 0.75A
0 ~ 1.5A
0 ~ 0.75A
36W 36W
4.3A 3.11A
0 ~ 4.3A 0 ~ 3.11A
21.5W 28W
See page 3 ; Other type available by customer requested
See page 3 ; Other type available by customer requested
85 ~ 264VAC
82% 86% 87.5% 88.5% 90%
110 ~ 140% rated output voltage
1000ms, 30ms, 50ms/230VAC 1500ms, 30ms, 13ms/115VAC at full load
110 ~ 150% rated output power
0.8A / 115VAC 0.45A / 230VAC
35A / 115VAC 70A / 230VAC
209g; 60pcs/13.5Kg/1.22CUFT
-30 ~ +70 (Refer to "Derating Curve")
-40 ~ +85 , 10 ~ 95% RH
±℃0.03% / (0 ~ 50 )
VOLTAGE RANGE Note.7
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load.
7.Derating may be needed under low input voltage. Please check the derating curve for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)