Datasheet
SPECIFICATION
GST280A series
File Name:GST280A-SPEC 2015-09-07
ORDER NO.
DC VOLTAGE
Note.2
SAFETY MODEL NO.
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.)
Note.3
OUTPUT
VOLTAGE RANGE
Note.7
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 8)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
GST280A15
GST280A15-C6P
GST280A12
GST280A12-C6P
GST280A20
GST280A20-C6P
GST280A24
GST280A24-C6P
GST280A48
GST280A48-C6P
15V12V 20V 24V 48V
120mVp-p120mVp-p 150mVp-p 280mVp-p 280mVp-p
VOLTAGE TOLERANCE
Note.4
LINE REGULATION
Note.5
LOAD REGULATION
±5.0%±5.0% ±4.0% ±3.0% ±2.0%
±1.0%±1.0% ±1.0% ±1.0% ±1.0%
±5.0%±5.0% ±4.0% ±3.0% ±2.0%
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
PF>0.95 / 230VAC PF>0.98 / 115VAC at full load
90%
89.5%
92% 93% 94%
3A / 115VAC 1.5A / 230VAC
120A / 230VAC
1.5mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P: 3KVAC I/P-F/G: 2KVAC O/P-F/G: SHORT
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
181.24Khrs min. MIL-HDBK-217F(25 )℃
-30 ~ +70 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃℃0.03% / (0~40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
220*95*46mm (L*W*H)
1.25Kg; 12pcs/16Kg/1.27CUFT
CONNECTOR
PLUG
CABLE
See page 3 ; Other type available by customer requested
See page 3 ; Other type available by customer requested
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Derating may be needed under low input voltage. Please check the derating curve for more details.
8. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254 GB17625.1
OVERLOAD
OVER VOLTAGE
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
17A21A 13A 11.67A 5.84A
0 ~ 17A0 ~ 21A 0 ~ 13A 0 ~ 11.67A
0 ~ 5.84A
255W252W 260W 280.08W 280.32W
Protection type : Shut down o/p voltage, re-power on to recover
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, approved
PSE J60950-1
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
2000ms, 20ms / 230VAC 2000ms, 20ms / 115VAC at full load
16ms / 230VAC 16ms / 115VAC at full load
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover
EMC IMMUNITY
EMC EMISSION
280W AC-DC High Reliability Industrial Adaptor